Maintenance

FLOW CONTROL

The flow control is required for proper operation of the

Reverse Osmosis system. See Fig. 29. The flow control,

located inside the push-in elbow fitting on the drain port of

the system housing, keeps water flowing through the mem-

brane at the required rate. This ensures that the system pro-

duces the best quality product water.
Periodically check the flow control to be sure the small hole

through it is clean and unrestricted.
If the flow control requires service, review the exploded view

in Fig. 29. Assemble and disassemble as shown. If the flow

control remains in the manifold when the push-in elbow fit-

ting is removed, you will need to remove the drain port’s col-

let and o-ring, as shown in the next section, to retrieve it.

CHANGE COLLET AND O-RING

1. Remove the collet and o-ring from the fitting with a small

screwdriver. Do not scratch the internal walls of the collet

port. See Figs. 30 & 31.

2. Clean collet port, lubricate with silicone-based lubricant,

and insert the o-ring seal into the bottom of the port. See

Figs. 30 & 31.

3. Push the collet inward until it locks in place. See Figs. 30

& 31.

CHANGE BATTERY

To change battery, complete the following steps.
1. Remove the screw on the right side of the faucet base.

See Fig. 32.

2. Press the battery housing upwards from the front faucet

base until it releases from the faucet base. See Fig. 32.

3. Replace the battery (CR 2032 or equivalent). Place bat-

tery into the holder with the positive (+) side facing the

back of the holder.

4. When the battery is installed the LED will flash six times

and turn off. This indicates the battery is fully charged.

After the six flashes, the timer enters the 6 month time

cycle. If it repeatedly flashes two times, it is not a fully

charged battery.

5. Re-install the battery housing and firmly tighten the mount-

ing screw. See Fig. 32.

Battery

Housing

Battery,

negative (–)

side facing

the front

Faucet

Base

Screw

FIG. 32

Change Collet and O-Ring

FIG. 30

Collet

Fitting

O-Ring Seal

Push o-ring seal into

bottom of port then

follow with collet.

Disconnect Tubing

FIG. 31

Tubing

Collet (depress to

remove tubing)

To

Drain

FIG. 29

Flow Control

Insert

Push-in

Elbow Fitting

1/4” Red

Tubing