Step g - sanitize, test and purge system – EcoPure ECOP30 User Manual
Page 18
18
Step G - Sanitize, Test and Purge System
SANITIZE THE SYSTEM
Sanitizing is recommended immediately after installa-
tion of the Reverse Osmosis system. It’s also recom-
mended after servicing inner parts. It is important that
the person installing or servicing the system have
clean hands while handling inner parts of the system.
Complete the following steps to sanitize the system.
See Fig. 25.
1. Make sure that the water supply to the Reverse
Osmosis system is off.
2. Open the Reverse Osmosis faucet. If the tank is
not already empty, allow the water to empty.
3. Locate the eyedropper included in parts bag and
common household bleach (5.25%).
4. Add 3 ml. of bleach into open end of yellow tubing.
Handle bleach according to bleach manufacturer’s
recommendations. See Fig. 25.
5. Connect yellow tubing to tank connector. See Figs.
14 and 25.
6. Sanitizing the system will be completed during the
pressure test and purging steps on the following
page.
NOTE: The bleach must be removed from the
system before drinking the water. See purging
instructions on the next page.
FIG. 25
RO Sanitization
Cartridge
Postfilter
Sanitization
Cartridge
Prefilter
Sanitization
Cartridge
This reusable sanitizing kit (not included) is
recommended to easily and completely sani-
tize your Reverse Osmosis system annually.
The kit includes the following:
=
Prefilter sanitization cartridge
(contains no filtration media)
=
Postfilter sanitization cartridge
(contains no filtration media)
=
RO sanitization cartridge
(contains no RO membrane)
=
Syringe, 1 oz.
=
Complete instructions
Uses standard 5.25% household bleach (not
included) to completely sanitize the Reverse
Osmosis system.
Manufacturer recommends using the
Model 7301203 Sanitizing Kit
To order, go to
www.ecodynewatertreatment.com
and click on the “Replacement Parts” link under the “Owner Center” tab,
or call toll free
1-800-693-1138
Monday - Friday, 7 AM - 6 PM CST