beautypg.com

Specifications, 5getting started – Dynalco SST-2400H Speed Switch/Transmitter User Manual

Page 8

background image

Specifications

Electrical

Input Signal

Frequency

Range

t

0-20 kHz (standard) (field-adjustable)

t

0-0.1 Hz (special order)

t

0-80 Hz (special order)

t

0-50K Hz (special order)

Waveforms

t

Accepts pulsed, sinusoidal, square, TTL, or CMOS

Input Signal

Sensitivity

t

25 mVrms (typical factory setting)

t

5 mVrms to 100 mVrms (field-adjustable)

t

50 Vrms (maximum for standard units)

t

1.0 volt threshold (requires input signal desensitizing)

Input

Impedance

t

Nearly infinite at low signal levels

t

10 k

(min.) at signals exceeding +15.0 V peak, –1.0 V peak

Power Input

t

115 Vac ±10%, 47-420 Hz

t

22–30 Vdc, maximum 5 W or 150 mAdc

t

220 Vac, 50/60 Hz (optional)

Proportional

Output

t

0–1 mAdc (standard)

t

4–20 mAdc (standard)

t

0–5 Vdc or 0–10Vdc (field-selectable; for external load

resistance of 20 k

or higher)

t

Custom ranges available

MAXIMUM LOAD

t

1 k

with 115/ 220 Vac or 30 Vdc power

t

750 ohms with 22 Vdc power

t

linear between 22 and 30 Vdc

Output Current

Independent of load resistance up to the rated load resistance

Span/zero adj.

±5% (minimum) of fuIl-scale

Auxiliary

Meter Output

Proportional 0–1 mAdc, filtered, for meter or recorder loads up

to 750

.

Supply Output

Regulated +14 Vdc ±5%; 40 mAdc (maximum load)

Repeater

Output

Square wave 14 V peak-to-peak, zero based, positive going

Output Ripple

and Noise

0.1% of full-scale maximum over 10% to 100% of full-scale.

Response Time

150 milliseconds, 10% to 90% rise (standard). Full-scale

frequency ranges below 80 Hz are proportionally slower.

Linearity

0.1% of full-scale (0.05%, typical), all outputs.

Stability

Less than 0.05% of full-scale change with a 10% change in

supply voltage. Temp. coeff. ±0.01% per °F (±0.018% per °C)

5

Getting Started