beautypg.com

Warning – Char-Broil 463420509 User Manual

Page 9

background image

9

WARNING

If “growing” bubbles appear do not use or move the LP tank.
Contact an LP gas supplier or your fire department!

LP Tank Exchange

• Many retailers that sell grills offer you the option of replacing

your empty LP tank through an exchange service. Use only
those reputable exchange companies that inspect, precision fill,
test and certify their cylinders.

Exchange your tank only for

an OPD safety feature-equipped tank as described in the

"LP Tank" section of this manual.

Always keep new and exchanged LP tanks in upright position

during use, transit or storage.

Leak test new and exchanged LP tanks BEFORE

connecting to grill.

LP Tank Leak Test

For your safety
Leak test must be repeated each time LP tank is exchanged or

refilled.

Do not smoke during leak test.
Do not use an open flame to check for gas leaks.
Grill must be leak tested outdoors in a well-ventilated area,

away from ignition sources such as gas fired or electrical
appliances. During leak test, keep grill away from open flames
or sparks.

• Use a clean paintbrush and a 50/50 mild soap and water

solution.

s

Do not use household cleaning agents. Damage to gas

train components can result.

Brush soapy solution onto areas indicated by arrows

in figure below. Leaks are indicated by growing bubbles.

Connecting Regulator To The LP Tank

1. LP tank must be properly secured onto grill. (Refer to

assembly section.)

2. Turn all control knobs to the OFF position.
3. Turn LP tank OFF by turning OPD hand wheel clockwise to a

full stop.

4. Remove the protective cap from LP tank valve. Always use

cap and strap supplied with valve.

Safety Relief Valve

Nipple has to be centered

into the LP tank valve.

OPD Hand Wheel

Type 1 outlet with

thread on outside

ck

w

o

l

is

C

e

f

f

O

Do not use a POL transport plug

(plastic part with external threads)!

It will defeat the safety feature of

the valve.

5. Hold regulator and insert nipple into LP

tank valve. Hand-tighten the coupling
nut, holding regulator in a straight line
with LP tank valve so as not to cross-
thread the connection.

Strap and Cap