Table 8 (Continued)

Application

Resin

Reference

Trace element separa-

AG 50W-X8

Faisca, A. M. M. M., et al., Anal.

tion from manganese

resin

Chim. Acta, 215, 317 (1988).

Rare earth element

AG 50W-X8

Juras, S. J., et al., Chem. Geol.,

separation

resin

64 (1-2), 143 (1987).

Platinum and palla-

AG 50W-X8

Brown, R. J. and Biggs, W. R.,

dium determination

resin

Anal. Chem., 56 (4), 646 (1984).

Chromium thiocyanate

AG 50W-X8

Collins, C. H. and Lancas, F. M.,

hydrate analysis

resin

Radiochem. Radioanal. Lett., 56
(2), 117 (1983).

Copper determination

AG 50W-X8

Victor, A. H., Geostand. Newsl., 7

resin

(1), 227 (1983).

Rare earth element

AG 50W-X8

Savoyant, L., Persin, F. and

determination

resin

Dupuy, C., Geostsnd. Newsl., 8
(2), 159 (1984).

Lead separations

AG MP-50

Strelow, F. W. E., Anal. Chem., 57

resin

(12), 2268 (1985).

Copper detection

AG 50 resin

Lazaro, F., et al., Anal. Chim.
Acta,
214, 217 (1988).

Iron detection in wine

AG 50W-X8

Ajlec, R. and Stupar, J., Analyst,

resin

114, 137 (1989).

Rare earth metal

AG 50W-X8

Hiramatsu, K. and Yamada, T.,

separation

resin

Jpn. Kokai Tokkyo Koho,
September 1988.

23

Table 8 (Continued)

Recommended Eluant and

Metals

Resin

Eluted ions

Reference

V, U, Sc, Y AG 50W-X8

V - 0.25 M H

2

SO

4

; Strelow, F. W. E.,

resin

U - 0.5 M H

2

SO

4

;

Rethemeyer, R. and

Sc - 1 M H

2

SO

4

;

Bothma,C. J. C., Anal.

Y 4 N HCI

Chem., 37, 106 (1965).

Be, Ba, Sr

AG 50W X8

Be, Ba-9 M HCl0

4

; Nelson, F., Murase, T.

resin

Sr-5 M HN0

3

and Kraus, K. A., J.
Chromatog.,
13, 503
(1984).

K, Ti, Sc

AG 50W X8

K-9 M HClO

4

;

Nelson, F., Murase, T.

resin

Ti-9 M HCI;

and Kraus, K. A., J.

Sc-4 M HCI,

Chromatog., 13, 504

0.1 M HF

(1964).

Application

Resin

Reference

Metal separation (Pm,

AG 50W-X12 Jerome, S. M., The Science of the

Y, Eu, Co, Fe, Am, Cm, resin

Total Environment, 70, 275

Nd)

(1988).

III

ln separated from

AG 50W-X4

Van der Walt, T. N., et al., Int. J.

cyclotron target

resin

Appl. Radiat. Isot., 36 (6), 501
(1985).

Cobalt separation

AG 50W-X4

Victor, A. H., S. Afr. J. Chem., 36

resin

(2), 76 (1983).

Trace metal separation

AG 50W-X4

Van der Walt, T. N. and Strelow,

resin

F. W. E., Anal. Chem., 55 (2),
212 (1983).

Thorium detection

AG 50W-X4

Victor, A. H. and Strelow, F. W.

resin

E., Anal. Chim. Acta, 138, 285
(1982).

22