safety
WARNING
Serious injury or death may occur from an air tank
explosion if air tanks are not properly maintained.
Serious injury may occur from an air compressor
malfunction or exploding accessories if incorrect system
components, attachments or accessories are used.
Serious injury or death may occur if system safety’s are
not properly maintained.
Serious injury or death may occur from the battery.
• Drain air tank daily or after each use to prevent moisture buildup in the
air tank.
• If air tank develops a leak, replace the air tank immediately. Never
repair, weld or make modifications to the air tank or its attachments.
Use only genuine BE repair parts for your air compressor.
• Never make adjustments to the factory set pressures.
• Never exceed manufacturers maximum allowable pressure rating of
attachments.
• Because of extreme heat, do not use plastic pipe or lead tin soldered
joints for a discharge line.
• Never use air compressor to inflate small, low pressure objects such
as toys.
• Safety pressure Relief Valves should never be altered, modified,
removed or made inoperative. If the device fails, replace immediately
with genuine manufacturer replacement part.
• When the battery is being activated, hydrogen and oxygen gases in
the battery are extremely explosive. Keep open sparks and flames
away from the battery at all times, especially when charging the
battery.
• Be certain to disconnect the battery ground terminal before servicing.
When disconnecting the cable from the battery, start with the
negative terminal, and when connecting them start with the positive
cable.
• When charting the battery remove the battery vent plugs.
• Use only a voltmeter or hydrometer to check battery charge.
• DO NOT jump start the battery unless both batteries are of equal
voltage and amperage.