Specifications, cont, Headloss charts – Baseline Systems BHM Series Hydrometer User Manual
Page 6

6
• Hydrometers Operation and Maintenance Manual
Specifications, Cont.
6”
8”
5.0
4.0
3.0
2.0
1.0
0
50
100
150
200
250
1 ½”
2”
3”
Headloss Charts
Headloss
(psi)
Headloss
(psi)
5.0
4.0
3.0
2.0
1.0
0
200
400
600
800
1000
1200
1400
4”
Flow Rate (gpm)
Flow Rate (gpm)
Lowest Flow
within ± 5% Accuracy
1 ½”
2”
3”
4”
6”
8”
1.8 GPM
4.4 GPM
44 GPM
55 GPM
5.3 GPM
20 GPM
66 GPM
95 GPM
14 GPM
53 GPM
176 GPM
220 GPM
21 GPM
79 GPM
264 GPM
380 GPM
53 GPM
198 GPM
660 GPM
860 GPM
97 GPM
357 GPM
1,189 GPM
1,500 GPM
Lowest Flow
within ± 2% Accuracy
Size
Nominal Flow
within ± 2% Accuracy
Maximum Flow
within ± 2% Accuracy
Performance Data
Cv (Flow Rate at
1.0 psi of Headloss)
1 ½”
2”
3”
4”
6”
8”
23 GPM
35 GPM
92 GPM
139 GPM
347 GPM
624 GPM
Size
Cv Values
Pressure loss in psi = (gpm/Cv)
^2
Example: 2” Hydrometer, design flow @ 97 gpm
(55 gpm/35 gpm)
^2
= 2.5 psi headloss