Tank Level Sensing Processor and Sensors
Page 10
7
Setup
7.1 Configuration
7.1.1
Sensor Inputs
The TLSP has the ability to accept inputs from up to 12 sensors. In the majority of cases not
all 12 will be used so the TLSP will require configuration in order that it should know which
tank input controls which tank function.
ú Scroll to the ‘TANKS’ menu on the FFD, press ENTER.
ú Scroll to ‘CONFIG’, press ENTER.
ú Scroll to ‘CALIBRATE’ on the opposite side of the display.
ú Select the number of tanks and inputs to be made available. For example, if 4 tank sensors
are fitted set this value to 4. This will enable the inputs 1-4 on the TLSP.
Only select the number of sensors actually fitted.
7.1.2 FFD Text
The text assigned to a tank may be selected from a range of pre-set text, or using a PC
attached to the TLSP, custom text may be assigned. When a sensor input has been
configured a default text legend will be applied to it as follows:
Sensor Input
FFD Text legend
1
P F BAL
2
P M BAL
3
P A BAL
4
S F BAL
5
S M BAL
6
S A BAL
7
WATER
8
P WATER
9
S WATER
10
FUEL
11
P FUEL
12
S FUEL
To change the text for a sensor input:
•
Scroll through the menu system to the desired tank.
•
Scroll to ‘CALBRATE’, on the opposite side of the display.
•
Press ENTER, Scroll to ‘CAL VAL 4’.
•
Press ENTER, a number corresponding to the text (see table above) is shown.
•
To change the text press ENTER, alter the display to your desired text, press ENTER
again to confirm.