Small seeds attachment rate, Small seeds rate handle, Small seeds rate calibration – Great Plains 2510HDF Operator Manual User Manual
Page 39
![background image](/manuals/599050/39/background.png)
Great Plains Manufacturing, Inc.
Adjustments
35
2013-11-11
288-340M
Small Seeds Attachment Rate
Small seeds attachment box planting rate is controlled
by:
• Seed Rate handle setting
Small seeds rate is independent of the Drive Type used
for main seed box planting. The small seeds cups do not
have doors to adjust.
Before setting the rate, raise the drill and rotate the
gauge wheels. Check that seed meters, seed tubes and
drives are working properly and are free from foreign
material.
The procedure for setting the main box rate is:
1.
Consult the charts for your crop in the Seed Rate
manual. That provides the initial Rate Handle set-
tings.
2.
Configure Seed Rate handle on one or both sides of
the drill.
3.
Calibrate the drill for your specific seed.
4.
Set both rate handles identically.
Small Seeds Rate Handle
Refer to Figure 29
Position the small seeds seed cup lever to setting
indicated on the Rate Chart in the Seed Rate manual.
To adjust:
1.
Loosen wing nut
under handle
.
2.
Slide handle
until indicator is about 10 past the
desired value, then move it back to the desired value.
3.
Tighten wing nut.
Small Seeds Rate Calibration
Note: You may need to increase seed cup setting for light-
er than average seed or decrease seed cup setting
for heavier than average seed.
Note: The seed rate charts are based on cleaned, un-
treated seed of average size and test weight. For
seed not listed on the charts, compare weight and
size to those listed and use a similar setting.
Figure 29 Small Seeds
Seed Cup Lever Adjustment
18511
1
2
1
2
2