Tractor hookup, Hydraulics electrical – Great Plains 3N-3020 Material Rate User Manual
Page 7
4/28/2004
196-366B
Great Plains Mfg., Inc.
7
Tractor Hookup
Hydraulics
1.
Connect pressure hose (P) to retraction out-
let.
2.
Connect motor return hose (T) to motor return
port (if available) or to extension outlet.
3.
Set flow rate at maximum.
4.
If tractor is equipped with elecro-hydraulic
valves, set timer to "constant" flow.
Electrical
1.
Power can be connected in three different
manners:
Refer to Figure 6
a.
Power port adaptor (PN 19676)
Refer to Figure 7
b.
To battery. Make sure that eyelets are
properly connected (red to positive, black
to negative). Connect female socket to
power port adapter.
c.
To 12V Power Box (PN 823-202C). Con-
nect red wire to 5 amp post and black wire
to center (ground) post.
Figure 6
Figure 7
Connect to
console
Connect to
power port
Connect to
power wire from
implement
Wire eyelets
Female socket