13

Installation

~ LCD Programming

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

To lock the front panel

1. Enter

the

System menu

2. Scroll through the menu items to select Lock Panel, and press Enter.

3. Select

On, and press Enter again.

To unlock the front panel

1. Attempt to adjust a parameter. The GT1524 prompts you for the passcode.

2. Begin entering the passcode. Once you have correctly entered the fifth

character, the front panel unlocks. (The default passcode for all units is Up,

Up, Down, Down, Enter.)

Set Passcode

Once you have unlocked the GT1524, you can change the passcode. Before the

GT1524 allows passcode changes, the new passcode must be entered, then re-entered

to validate it. The passcode must be five front panel buttons (in any combination or

multiple).

RS-232

Two RS-232 parameters can be adjusted through the front panel LCD: baud rate and

flow control. If data is lost during serial access through the RS-232 port, a serial

overrun error will occur. This is indicated on the LCD display. This parameter sets

the GT1524’s RS-232 port communication rate at 9,600 (default), 19,200, or

38,400 baud (bps).

Baud. To set the baud rate, scroll through the settings to select the desired baud

rate, then press Enter.

Flow Control. The flow control parameter allows activation and deactivation of

hardware flow control. The two options are On and Off (default). To activate the flow

control, scroll to On and press Enter. To deactivate it, scroll to Off and press Enter.

Telco

Auto-Answer On/Off. This parameter sets the telephone interface to automatically

answer an incoming call (Auto-Answer On), or allow the call to be handled manually

(Auto-Answer Off).

Auto-Disconnect. The interface can also be set to disconnect upon Loop Drop, Call

Progress, Loop Drop + CP, or to disconnect manually (Auto-Disconnect Off).