FURNACE COMPONENTS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

16

17

18

19

5

15

A07609

Fig. 2 -- Model 58MVC Furnace

1. Combustion--air intake connection to ensure contaminant--

free air (right or left side).

2. Burner sight glass for viewing burner flame.

3. Burner assembly (inside). Operates with energy--saving

inshot burners and hot surface igniter for safe, dependable

heating.

4. Redundant gas valve. Safe and efficient. Features 1 gas

control with 2 internal shutoff valves and one throttling
valve.

5. Vent outlet. Uses PVC pipe to carry flue gas from the

furnace’s combustion system (right or left side).

6. Inducer motor. Pulls hot flue gases through the heat

exchangers, maintaining negative pressure for added safety.

7. Blower access panel safety interlock switch.

8. Air filter and retainer (location in furnace may vary).

9. Condensate drain connection. Collects moisture condensed

from burned gases for disposal into home drain system.

(Location in furnace varies.)

10. Heavy--duty blower. Circulates air across the heat

exchangers to transfer heat into the home.

11. Everlastict Secondary condensing heat exchanger (inside).

Wrings out more heat through condensation. Constructed

with polypropylene--laminated steel to ensure durability.

12. Primary serpentine heat exchanger (inside). Stretches fuel

dollars with the S--shaped heat--flow design. Solid

construction of corrosion--resistant aluminized steel means
reliability.

13. Furnace control board.

14. 3--amp fuse provides electrical and component protection.

15. Light emitting diode (LED) on furnace control board. Status

code light is for diagnosing furnace operation and service
requirements.

16. Pressure switches ensure adequate flow of flue gas through

furnace and out vent system.

17. Rollout switch (manual reset) to prevent overtemperature.

18. Junction box for 115--v electrical power supply. (May be

located on right or left side)

19. Transformer (24v) behind furnace control board provides

low--voltage power to furnace control board and thermostat.