Salinity – LaMotte AG-104 Salt Water Aquarium User Manual
Page 14
SALINITY
QUAN TITY
CON TENTS
CODE
15 mL
*Salinity Indicator Reagent A
*7460-E
60 mL
*Salinity Titration Reagent B
*7461-H
60 mL
Demineralizer Bottle
1151
1
Test Tube, 5-10-15 mL, glass, w/cap
0778
1
Direct Reading Titrator, 0-20 Range
0378
1
Direct Reading Titrator, 0-1.0 Range
0376
*WARNING: Reagents marked with a * are considered to be potential health hazards.
To view or print a Material Safety Data Sheet (MSDS) for these reagents see MSDS
CD or www.lamotte.com. To obtain a printed copy, contact LaMotte by email, phone
or fax.
NOTE:
Read Demineralizer Bottle instructions and Direct Reading
Titrator Manual before performing test.
TEST RANGE:
0-20 ppt Salinity
Pro ce dure
1.
Fill test tube (0778) to 10 mL line with Demineralized Water
(1151).
2. Fill the 1.0 mL Titrator (0376) to 0 mark with sample water. Wipe
any excess water off the Titrator.
3. Dispense 0.5 mL of sample water into test tube by depressing
plunger until tip is at 0.5 mark. Discard remaining water in Titrator.
4. Add 3 drops of *Salinity Indicator Reagent A (7460). Cap and
gently swirl to mix.
5. Fill 0-20 Direct Reading Titrator (0378) with *Salinity Titration
Reagent B (7461). Insert Titrator in hole of test tube cap.
6. While gently swirling the tube, slowly depress plunger to titrate
sample until yellow color changes to pink-brown. Read test result
directly from the scale where the large ring on the Titrator meets
the Titrator barrel. Each minor Titrator division = 0.4 ppt Salinity.
EXAMPLE:
Plunger tip is 3 minor divisions below 10, test result is
10 plus (3 x 0.4) = 11.2 ppt.