fIGURE 3

SPECIAL INfORMATION

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting etc.)

Be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor,

turbine, engine, etc.) has been “locked

out” or made non-operational so that

it cannot be started while work is

being done on pump.

3. That you know what liquid the

pump has been handling and the

precautions necessary to safely

handle the liquid. Obtain a material

safety data sheet (MSDS) for the

liquid to be sure these precautions

are understood.

failure to follow above listed

precautionary measures may result in

serious injury or death.

ROTATION: Viking Mag Drive

®

pumps are directional

Shaft rotation determines which port is suction and which is

discharge The port located where pumping elements (gear

teeth) come out of mesh is the suction port Do not attempt

to operate the pump in the opposite direction See

PUMP

ROTATION on page 7

PRESSURE RELIEf VALVES:

1. Viking pumps are positive displacement pumps and must

be provided with some sort of pressure protection This

may be a relief valve mounted directly on the pump, an

inline pressure relief valve, a torque limiting device or a

rupture disk Do not rely on decoupling of magnets for

protection from over pressure; this may result in damage

to the magnets, pump, or other equipment

2. If pump rotation is to be reversed during operation,

pressure protection must be provided on both sides of

the pump

3. The relief valve adjusting screw cap must always point

towards the suction side of the pump Refer to

figure 3. If

the pump rotation is reversed, remove the pressure relief

valve and turn end for end (see

PUMP ROTATION on

page 7 first for additional steps required for proper

operation )

4. Pressure relief valves cannot be used to control pump

flow or regulate discharge pressure

For additional information on pressure relief valves,

refer

to Technical Service Manual TSM000 and Engineering

Service Bulletin ESB-31.

CAUTION !

Rare earth magnets used in these

couplings have extremely strong

magnetic fields capable of changing the

performance or damaging items such as

the following:
Pacemakers

Metal Implants

Watches

Computers & discs

Credit Cards

Completely assembled magnetic

couplings will not affect items listed

above.
Altered performance or damage can

occur only when the coupling halves are

separated.
There are no known harmful effects of

these magnetic fields on the human

body.

SUCTION

DISCHARGE

RELIEf VALVE ADJUSTING SCREW CAP

MAINTENANCE