beautypg.com

Technical service manual, Caution – Viking Pump TSM845.1: LQ-QS 825, 823, 827 User Manual

Page 13

background image

SECTION TSM 845.1
PAGE

13 Of 13

ISSUE

E

MAGNETIC DRIVE PUMPS

SERIES 823 - STEEL

825 - CAST IRON

827 - STAINLESS STEEL

SIZES LQ, LS, Q & QS

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

CAUTION !

TO REDUCE THE RISK Of LEAKAGE WITH VIKING

MAG DRIVE PUMPS, USERS SHOULD COMPLY

WITH THE fOLLOWING GUIDELINES AND ADHERE

TO THE fOLLOWING PROCEDURES:
■ The pump configuration and materials used in a pump

are tailored to the application for which it is ordered

Users should never use a pump for an application

that is different from the application specified when

the pump was ordered This includes differences in

liquid, speed, pressure, temperature or viscosity

■ Users must understand the characteristics of liquids

they are pumping and be especially aware of any

particulates in the liquid Particulates can cause

rapid wear of the bushings, especially if carbon

graphite bushings are used Hard bushings and

hard shafts can reduce the risk of rapid wear, but

the use of hard materials is not always the optimal

solution In applications involving non-abrasive, non-

self lubricating liquids, carbon graphite bushings are

typically the preferred material

■ Users should periodically inspect their pump for

wear This is especially critical and should be

carried out with greater frequency when carbon

graphite bushings are used or the same pump has

not previously been used for the same application,

including the same liquid, speed, pressure,

temperature and viscosity Users should promptly

replace worn parts when they are discovered

■ Users should continuously monitor pumps that are

handling hazardous liquids This is especially critical

for unmanned, remote locations If a user does not

have in-house expertise in the area of monitoring,

it should contact a local engineering firm with

monitoring experience