FIGURE 4 - EXPLODED VIEW SERIES 4123A, 4124A, 4124AE, 4126A, AND 4127A MODELS
ITEM
NAME OF PART
ITEM
NAME OF PART
ITEM
NAME OF PART
1
Locknut
10
Cartridge Seal
19
Idler and Bushing Assembly
2
Lockwasher
11
Capscrew for Bracket
20
Idler Bushing
3
End Cap
12
Grease Fitting
21
Head Gasket
4
Lip Seal
13
Bracket and Bushing Assembly
22
Idler Pin
5
Bearing Spacer Collar (Outer)
14
Bracket Bushing
23
Head and Idler Pin Assembly
6
Ball Bearing
15
Bracket Gasket
24
Capscrew for Head
7
Bearing Spacer Collar (Inner)
16
Pipe Plug
25
Relief Valve Gasket
8
Ring, Half Round (Not H, HL)
17
Casing (Tapped or Flanged)
26
Internal Relief Valve
9
Bearing Housing
18
Rotor and Shaft Assembly
27
Capscrew for Valve
REPAIR: MODELS H, HL, K, KK, L, LQ AND LL
CARTRIDGE MECHANICAL SEAL PUMPS
DANGER !
Before opening any Viking pump liquid
chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.)
Be sure:
1. That any pressure in the chamber has
been completely vented through the
suction or discharge lines or other
appropriate openings or connections.
2. That the driving means (motor,
turbine, engine, etc.) has been “locked
out” or made non-operational so that
it cannot be started while work is
being done on pump.
3. That you know what liquid the
pump has been handling and the
precautions necessary to safely
handle the liquid. Obtain a material
safety data sheet (MSDS) for the
liquid to be sure these precautions
are understood.
Failure to follow above listed
precautionary measures may result in
serious injury or death.
CARTRIDGE MECHANICAL
SEAL REPLACEMENT
CARTRIDGE MECHANICAL
SEAL REMOVAL
MODELS:
H, HL, K, KK, L ,LQ, LL4124A AND LL4124AE CAST IRON
H, HL, K, KK, L, LQ, AND LL4126A DUCTILE IRON
H, HL, K, KK, LQ, AND LL4123A STEEL
H, HL, K, KK, LQ, AND LL4127A STAINLESS STEEL
For complete pump disassembly and assembly see
pages 7 and 8.
1. Bend up tang of lockwasher and with a spanner wrench,
remove locknut and lockwasher from shaft.
2. Loosen two set screws in the face of the bearing housing
and remove the bearing housing assembly from the
bracket.
3. Remove the pair of half round rings under the inner
spacer collar from the shaft. There are no half round
rings on the “H” and “HL” size pumps.
4. If flush or barrier fluid tubes are connected to the seal
gland, disconnect before removing seal. Loosen the set
screws on the cartridge seal collar to free the cartridge
seal from the shaft. Remove the two gland capscrews
and slide cartridge seal out through bearing housing
opening.