Rear panel connections – VICI 450 Dynacalibrator User Manual
Page 15

11
Rear Panel Connections
Remove all shipping caps and shipping plugs from the rear panel bulkhead fit-
tings. All these hardware items should be saved for reuse if the Dynacalibrator
must be stored or returned to VICI.
The connections available on the rear panel of the different models and con-
figurations are listed in Table 1. If a plumbing connection is required, the block
under the fitting heading is marked with an “X”; if the connection is optional, the
block is marked with an “O”; if there is no connection, the block is blank.
Fitting locations are identical for all configurations. Fitting holes which are not
used are equipped with blank caps. All connections are clearly marked and
easily identified.
Table 1: Dynacalibrator Model 450 rear panel connections
Getting Started
Figure 6: All rear panels connections
are clearly marked
11
Rear Panel Connections
Remove all shipping caps and shipping plugs from the rear panel bulkhead fit-
tings. All these hardware items should be saved for reuse if the Dynacalibrator
must be stored or returned to VICI.
The connections available on the rear panel of the different models and con-
figurations are listed in Table 1. If a plumbing connection is required, the block
under the fitting heading is marked with an “X”; if the connection is optional, the
block is marked with an “O”; if there is no connection, the block is blank.
Fitting locations are identical for all configurations. Fitting holes which are not
used are equipped with blank caps. All connections are clearly marked and
easily identified.
Model
Inlets
Outlets
Bypasses
Vents
Sample
Supply
Carrier
Dilution Stream
Span
Zero
Carrier
Dilution Overflow
Chamber
450-0X
O
X
X
O
O
450-1X
O
X
X
X
O
O
450-2X
O
O
X
O
O
450-3X
O
O
O
X
O
O
450-4X
O
O
O
X
X
O
O
450-5X
O
O
O
O
X
X
O
O
450-0X-Z
O
X
X
X
O
O
450-1X-Z
O
X
X
X
X
O
O
450-2X-Z
O
O
X
X
O
O
450-3X-Z
O
O
O
X
X
X
O
O
450-4X-Z
O
O
O
X
X
X
O
O
450-5X-Z
O
O
O
O
X
X
X
X
O
O
X = Required connection
O = Optional connection
blank = No connection
Table 1: Dynacalibrator Model 450 rear panel connections
Getting Started
Figure 6: All rear panels connections
are clearly marked
SAMPLE
INLET
STREAM
OUTLET
SPAN
OUTLET
ZERO
OUTLET
OVERFLOW
CHAMBER
VENTS
CARRIER
OUTLET
DILUTION
OUTLET
CARRIER
INLET
DILUTION
INLET
MAXIMUM PRESSURE
AT ANY PORT
MUST NOT EXCEED
15 PSIG
REPLACE ONLY WITH
VICI P/N I-X-PS150-24V
TO MAINTAIN PROPER
CE COMPLIANCE
REMOTE CONTROL
FACTORY SUPPLIED SOURCE
POWER INPUT
24V
6.25A
150W MAX VME
CHAMBER 2 (RS232)
CHAMBER 1 (RS232)
VALCO PART #
AC INPUT:100-240V~2.5A 50-60Hz
I-X-PS150-24V
PLEASE READ OPERATION
MANUAL BEFORE PROCEEDING
V1 V2 V3
C
Metronics Inc.
DYNACALIBRATOR
MODEL NO.
SERIAL NO.
XXX-XXXXX
XXX-XXXXX
PHONE 877-737-1887