MAGNUM 610E PUMP OPERATION / MAINTENANCE MANUAL

PAGE 5

1.4 UTILITIES / HOOK-UP FOR REMOTE CONTROLLER

The Magnum 610E pump will work with many types of external control devices.
TREBOR’s pneumatic Pump Control Module is recommended for its proven,
reliable performance. Please consult factory for assistance with other external
control devices.

1.4.a

Trebor’s Remote Oscillator

Air Inlet:

3/8” Dia. (8mm) supply tube (Use in-line 10µ air filter).

Air Supply:

20-80 psig (1.4

– 5.2 bar) clean dry air or nitrogen (see

Performance Charts, Section 3.1, for air consumption).

The mufflers on the optional Oscillator Control Module can be removed for
remote exhaust and purge connections.

Exhaust:

1/4” FNPT

Purge:

1/4” FNPT

Figure 1-2

1.4.b Electronic Oscillation Controller (example)

Air Inlet:

3/8” Dia. (8mm) supply tube (Use in-line 10µ air filter).

Air Supply to Pump:

20-80 psig (1.4-5.2 bar) clean dry air.

Solenoid Valve:

C

v

greater than .80, 3 position.

PLC/Electric Circuit:

For timed oscillation up to 260 cpm