beautypg.com

2 notes on safety for the customer / operator, 3 notes on safety for maintenance, 5 improper operation – Richter RMI Series User Manual

Page 6: 6 special requirements for explosion protection, 1 filling the unit, Notes on safety for the customer / operator 6, Notes on safety for maintenance, Parts by the customer, Improper operation, Filling the unit

background image

Series RMI

Page 6

9470-050-en

Revision 00

TM 7978

Edition 08/2010

Observe the instructions contained in the
operating manual or contractual documentation; if
necessary, consult the manufacturer.
All important features are documented in the data
sheet included in the scope of delivery.
In the event of operating conditions other than those
described in the data sheet, the following are to be
checked again:

design of the pump
design of the accessories
resistance of the materials.

2.2 Notes on safety for the

customer / operator

The following must be observed:

The notes on safety contained in this operating
manual,
the prevailing regulations on accident prevention,
in-house work, operating and safety regulations of
the customer.
Protect hot, cold or moving machine parts from
being touched on site.
Do not remove any protective facilities when the
machine is in operation.
Exclude any risks from electricity.
Remove leaks of hazardous media (e.g. explosive,
toxic, hot) so that there is no risk to people and the
environment. Observe statutory regulations.
Provide and use protective equipment for the staff.

Caution when using the units in potentially
explosive area!
Prevent inadmissible modes of operation.

2.3 Notes on safety for

maintenance

Strictly, work on the pump/unit may only be
performed when it is at a standstill.
The pump housing must have reached ambient
temperature.
The pump housing must be depressurized and
drained.
It is imperative to observe the procedure for
stopping the machine described in this operating
manual. See also Chapter 6.3.
Decontaminate pumps which convey media
hazardous to health.
Immediately after completion of the work, re-install
all safety and protective facilities or put them into
operation again.

When installed, the magnetic drives do not

represent any risk of environmental impact if the
notes on safety are observed (see also Chapters
5.1 and 7.5.2
).

It is imperative to observe the notes on
safety in Chapter 7.5.2 during dismantling
and assembly as well as during transport
and storage of magnetic drives as single
components.

Observe the points listed in Chapter 6.1 prior to
recommissioning.

2.4 Conversion work and

production of spare parts by
the customer

Conversion of or changes to the machine are only
admissible

after

consultation

with

the

manufacturer.
Only use original spare parts or parts approved by
the manufacturer.
The use of other parts may annul the liability for
any resultant consequences.

2.5 Improper operation

The operational safety of the machine supplied is
only guaranteed if it is used properly in accordance
with Chapter 2.1 of this operating manual.
The operating limits specified in the data sheet
must under no circumstances be exceeded.

2.6 Special requirements for

explosion protection

If the units are used in potentially explosive areas, the
measures and notes in Chapters 2.6.1 to 2.6.9 are
imperative to observe the explosion protection.

2.6.1 Filling the unit

During pump operation the wetted interior of
the pump must always be filled with the liquid
medium.

This prevents any explosive atmosphere and the risk
of dry-running.

If the customer cannot ensure this, we
recommend that appropriate monitoring
facilities be provided.

Also carefully fill auxiliary, heating and cooling
systems.