3
Transport, storage and disposal
The pump or the unit must be transported properly. It 
must be ensured that during transport the pump/unit 
remains in the horizontal position and does not slip 
out of the transport suspension points. 
A pump or motor can be suspended from the ring bolt 
provided for this purpose. 
The suspension points are not suitable for 
transporting a complete unit, i.e. pump with base 
plate and motor. 
In this case, the slinging points for the ropes on the 
base plate are to be used. See Fig. 1.
The slinging ropes must not be attached to free shaft 
ends or to the ring bolt of the motor. 
Fig. 1
Directly after receipt of the goods, the 
consignment must be checked for completeness 
and any in-transit damage. 
Damaged pumps must not be installed in the plant. 
When unpacking magnetic drives as single 
parts, the relevant notes in Section 7.5.2 
must be observed. 
Handle goods carefully to prevent damage. 
Flange covers serve as protection during transport 
and must not be removed. 
If the unit is not installed immediately after delivery, it 
must be put into proper storage. 
The product should be stored in a dry and vibration-
free, well ventilated room at as constant a 
temperature as possible. 
Elastomers are to be protected against UV light. 
In general, a storage period of 10 years should not be 
exceeded. An admissible storage period of 4 years 
applies to elastomers made of NBR. 
If magnetic drives are stored as single parts, the 
relevant notes in Section 7.5.2 are to be observed. 
In the case of prolonged storage conservation agents 
on machined component surfaces and packing with a 
desiccant may be necessary. 
 
3.1 Return consignments
Pumps which have conveyed aggressive or toxic 
media must be well flushed and cleaned before being 
returned to the manufacturer's works. 
It is imperative to enclose a safety information 
sheet / general safety certificate on the field of 
application with the return consignment. 
Pre-printed forms are enclosed with the installation 
and operating manual. 
Safety precautions and decontamination measures 
are to be mentioned. 
 
3.2 Disposal
Parts of the pump may be contaminated with medium 
which is detrimental to health and the environment 
and therefore cleaning is not sufficient. 
Risk of personal injury and damage to the 
environment due to the medium or oil! 
Wear protective clothing when work is performed 
on the pump. 
Prior to the disposal of the pump: 
Collect any medium, oil etc. which has 
escaped and dispose of it in accordance with 
the local regulations. 
Neutralise any medium residues in the pump. 
Separate pump materials (plastics, metals etc.) 
and dispose of them in accordance with the local 
regulations. 