7 maintenance, 1 safety-relevant screw fittings, 2 motor – Richter RMA-B Series (ASME) User Manual
Page 16: 3 cleaning, 4 stand-by pumps, 5 notes on dismantling, 1 protective clothing, 2 magnetic fields, 3 changing the motor, Safety-relevant screw fittings

Series RMA-B
close-coupled design
Page 16
9475-055-en
Revision 14
TM 8256
Edition 06/2011
7
Maintenance
7.1 Safety-relevant screw fittings
After initial loading by the operating pressure and 
operating temperature the tightening torques of all 
connection screws must be checked at the following 
points: 
housing flange 
suction flange 
discharge flange 
draining flange 
See also Chapter 6.1.1, para. 1.
Other inspections are to be performed regularly, 
depending on the operating requirements. 
 
7.2 Motor
Observe the operating manual of the motor 
manufacturer. 
A motor with a valid ATEX certificate is to be used if 
employed in zone 1 and 2. 
Observe the ATEX notes of the motor manufacturer. 
 
7.3 Cleaning
Care must be taken when cleaning the pump to 
ensure that it is not exposed to a strong water jet. 
 
7.4 Stand-by pumps
If a pump is on stand-by, it is to be started up from 
time to time. Regularly turn the shaft by hand in the 
direction of rotation. 
This operation is to be performed more often for 
pumps which are exposed to very strong vibrations 
from the plant. 
When dismantling the pump from the plant, drain it, 
thoroughly clean it, seal with flange covers and store 
in accordance with the instructions. 
 
7.5 Notes on dismantling
All repair and maintenance work is to be 
performed by skilled staff using appropriate tools 
and original spare parts. 
Is the necessary documentation available? 
Has the pump been shut down, drained and 
flushed in accordance with the regulations? 
See also Chapter 6.3.
If no new assembly is performed immediately after 
dismantling, the plastic and ceramic components 
in particular must be stored carefully. 
Dismantling can be checked using the sectional 
drawing in Chapter 9 and the components 
available. 
7.5.1 Protective clothing
Even if the pump has been properly 
evacuated and flushed, residue of the 
medium may still remain in the pump, e.g. 
between sealing surfaces or in the bearing seats or 
in the can. 
Plastic components may absorb medium which 
gradually emerges from the material after flushing. 
Proper protective clothing is to be worn.
Protective clothing is also to be worn even if only the 
adapter is to be removed. Medium may penetrated 
the lantern chamber through the can. 
 
7.5.2 Magnetic fields
Caution! Strong magnetic fields 
Risk during dismantling and in the vicinity of 
magnetic drives as single parts. 
Remove loose parts and other magnetisable metals 
from the work bench. They could otherwise be 
attracted: Risk of accident!
Place any tools needed at a safe distance. 
Keep 
electronic
equipment
and
measuring
instruments at a distance. In cases of doubt consult 
the equipment manufacturer. 
Hold magnetic drives as single parts firmly or secure. 
Otherwise they could be attracted, for example, by a 
vice: Risk of accident! 
People with an artificial pacemaker 
Keep torso at a minimum distance of 20"(500 mm). 
For safety's sake, a distance of 6" (150 mm) should 
be observed for watches, electric data carriers, data 
carriers with magnetic strips etc. 
 
7.5.3 Changing the motor
If the motor has to be changed, the pressure-bearing 
section of the pump can remain in the plant. 
For procedure, see Chapter 7.6.2.