Commissioning/Shutdown
6.1 Initial commissioning
Normally, the pumps have already been test-run with 
water. 
Unless special agreements have been reached, there 
may still be some residual amounts of water in the 
pump. This must be noted in view of a possible 
reaction with the medium. 
 
6.1.1 Filling the pump housing
Check to see whether the screws on the suction 
flange, discharge flange, housing flange and drain 
flange are tightened. When tightening the housing 
screws, it must be ensured that the screw fitting 
on the support bracket of the adapter and motor is 
undone. Otherwise, the pump may be subjected to 
tension. 
For screw tightening torques see Chapter 1.1.
Open the suction line fully so that the medium can 
flow into the pump. 
Open the discharge valve so that the air in the 
pump can escape. 
If air cannot be vented into the discharge line, e.g. 
a drop in pressure in this line is not permitted, 
venting must be performed upstream of the 
discharge valve. 
Monitor the venting operation until no air but only 
liquid emerges. 
Turn the pump shaft at the coupling several times. 
Monitor the venting operation again until no more 
air emerges. 
Close the discharge valve again until 
only the minimum flow rate is obtained 
after the motor has been started. 
6.1.2 Start-up
Check to see whether the pump shaft can be 
readily turned by hand. 
Check the direction of rotation of the motor with 
the coupling disengaged or with a rotary field 
instrument. 
As viewed from the motor, the direction of rotation 
of the pump is clockwise. See also the direction 
of rotation arrow of the pump. 
The pump must not run dry during the check 
of the direction of rotation. 
Check alignment of the coupling. 
Mount coupling guard. 
The pump must be completely filled with 
liquid. 
The maximum admissible flow rate must not be 
exceeded. 
Otherwise the plain bearings can run dry in 
both cases. 
Switch the motor on. 
Set the desired flow by opening the discharge 
valve. 
When the motor is running but the pump is not 
conveying, this means that the magnetic drive has 
stopped. 
Switch motor off immediately in order to prevent 
overheating of the magnet assemblies. 
Then proceeded as follows:
Close discharge valve down to the position 
"minimum flow rate" 
Start motor again. 
If the magnetic drive stops again, look for the cause. 
 
6.2 Operating limits
The operating limits of the pump/unit in 
terms of pressure, temperature, power and 
speed are entered in the data sheet and it is 
imperative to observe them! 
 
6.2.1 Abrasive media
If liquids with abrasive constituents are 
conveyed, increased wear at the pump is to 
be expected. The inspection intervals should 
be reduced compared with the usual times. 
 
6.2.2 Min./max. flow rate
The operating range generally recommended lies at 
0.3 Q
opt
to 1.1 Q
opt
. Consult the manufacturer for
operation outside this range and observe Chapter
2.6.2.