6. Remove wires from ignitor and sensor wires at the

Integrated Gas Unit Controller (IGC).

7. Remove the 2 screws that attach the burner rack to

the vestibule plate.

8. Slide the burner tray out of the unit (Fig. 50).

9. To reinstall, reverse the procedure outlined above.

B. Cleaning and Adjustment

1. Remove burner rack from unit as described in

Removal and Replacement of Gas Train section,
above.

2. Inspect burners; if dirty, remove burners from rack.

3. Using a soft brush, clean burners and cross-over port

as required.

4. Adjust spark gap. See Fig. 51.

5. Reinstall burners on rack.

6. Reinstall burner rack as described in Removal and

Replacement of Gas Train section, this page.

XVII. REPLACEMENT PARTS

A complete list of replacement parts may be obtained from
any Bryant distributor upon request.

Fig. 51 — Spark Gap Adjustment

580F090,091,102,103,120,121

180,000 BTUH INPUT

580F090,091,102,103

125,000 BTUH INPUT

580F090,091,102,103,120,121,150,151

220,000 BTUH INPUT AND 580F120,121,150,151

250,000 BTUH INPUT