Watts R48-20-3131100 User Manual
Page 16
IV.
REPLACEMENT PARTS LIST
Part Number
Description
Quantity per
System
S25FVS720
Pre filter housing 7 round 40"
1
R24449
Pressure Gauge, 2 1/2", 0-100 psi, LF, Back Mount
2
R2452P
Pressure Gauge, 2 1/2", 0-400 psi, LF, Back Mount
3
R5411
Flow Meter 15-130 gpm (product)
1
R5409
Flow Meter 10-80 gpm (reject)
1
R5398
Flow Meter 4 – 40 gpm (reject recycle)
1
R23-2000 Controller
with
conductivity meter (optional)
1
R6316-V70B10S3T Pump & Motor, 3-Phase, 60Hz, 20 hp
1
R2316-214B
Low Pressure Switch
1
R6154-3IV-24
Inlet Solenoid Valve 24 volt
1
R9642-TM370
RO Membranes
16
V. MEMBRANE REPLACEMENT
1. Turn off the system and close the feed water shutoff valve.
2. Disconnect the membrane feed hoses by loosing the brass fittings between the end of
the hoses and the pressure vessel end caps.
3. Remove the retaining rings from the pressure vessels.
4. Push the old membrane out of the vessel in the direction of the feed flow.
5. Record the serial numbers of the new membranes.
6. Lightly lubricate the brine seals on the new membranes with clean water.
7. Install the new membranes in the direction of flow with the brine seal end going in
last.
Note: Be sure to install an interconnector between the membranes in each
pressure vessel.
8. Lightly lubricate the end cap internal and external o-rings with glycerin.
9. Install the end caps and secure them with the retaining rings.
10. Install the membrane feed hoses.
11. Verify that all retaining rings are installed.
12. Follow the start up procedure in section III-D.
Flow Direction
Membrane Brine Seal