beautypg.com

3" (8 – 80mm), Troubleshooting guide – Watts LFU009 User Manual

Page 4

background image

Check Assemblies

Seat

Seat

O-ring

Disc

Assembly

Spring

Retainer

Cage

Seat

Flow Tube

Cover

Cover O-ring

Relief

Valve

Assembly

Body

Retainer

Second Check

Service Parts Kit

First Check

Service Parts Kit

CHECK ASSEMBLY

3

4

" M3

O-ring

Seal

Spring

Disc

Seat

Check

Cage

CHECK ASSEMBLY

1

4

" –

3

4

"

Injection Molded

Acetal Resin

O-ring Seal

Stainless Steel

Spring

Silicone Seal

1st Check

Module

Cover O-ring

Retainer

Second Check Assembly

First Check Assembly

Relief

Valve

Module

CHECK ASSEMBLY 1" - 2" (25 – 50mm)

Seat

Seat O-ring

Disc Assembly

Spring

Check Cage

RP/IS-009 1319

EDP# 1911300

© 2013 Watts

USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com

Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca

limited warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of

original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.

THE waRRanTy sET FORTH HEREin is GiVEn EXpREssly and is THE Only waRRanTy GiVEn By THE cOMpany wiTH REspEcT TO THE pROducT. THE cOMpany MaKEs nO OTHER

waRRanTiEs, EXpREss OR iMpliEd. THE cOMpany HEREBy spEciFically disclaiMs all OTHER waRRanTiEs, EXpREss OR iMpliEd, includinG BuT nOT liMiTEd TO THE iMpliEd

waRRanTiEs OF MERcHanTaBiliTy and FiTnEss FOR a paRTiculaR puRpOsE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special

or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting

from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no

control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above

limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to

determine your rights.

sO FaR as is cOnsisTEnT wiTH applicaBlE sTaTE law, any iMpliEd waRRanTiEs THaT May nOT BE disclaiMEd, includinG THE iMpliEd waRRanTiEs OF

MERcHanTaBiliTy and FiTnEss FOR a paRTiculaR puRpOsE, aRE liMiTEd in duRaTiOn TO OnE yEaR FROM THE daTE OF ORiGinal sHipMEnT.

A Watts Water Technologies Company

waRninG: This product contains chemicals known to the

State of California to cause cancer and birth defects or

other reproductive harm.

For more information: www.watts.com/prop65

Watts re serves the right to change or modify prod uct

de sign, con struc tion, spec i fi ca tions, or ma te ri als with out

prior notice and without in cur ring any obligation to make

such chang es and mod i fi ca tions on Watts prod ucts

previously or subsequently sold.

Troubleshooting Guide

Symptom

Cause

Solution

1. Check valve fails to hold

1.0 PSID minimum

a. Debris on check disc

sealing surface

Disassemble and clean

b. Leaking isolation valve

Disassemble and clean

or repair

c. Damaged seat disc or

seat o-ring

Disassemble and replace

d. Damaged guide holding

check open

Disassemble and clean or

replace

e. Weak or broken spring

Disassemble and replace

spring

2. Chatter during flow

conditions

a. Worn, damaged or

defective guide

Disassemble and repair

or replace guide

3. Low flows passing

through mainline valve

a. Mainline check fouled

Disassemble and clean

b. Meter strainer plugged

Disassemble and clean

c. Damaged mainline seat

disc or seat

Disassemble and replace

d. Broken mainline spring

Disassemble and replace

Servicing First & Second Check Valves