Direct Side Tapping

Vertical discharge line must be installed with its direction downward.

Max. 6"

(152mm)

Insulation

Discharge

Line

1

3

4

" to 3"

Discharge Line

Cold

Hot

T&P Relief

Valve

Max. 6"

(152mm)

Insulation

Series SL100XL, L100XL, LL100XL

and LLL100XL

Model SL100XL Suitable for water heaters with up to

1

3

4

" (44mm) of insulation

Model. L100XL Suitable for water heaters with up to

2" (50.8mm) of insulation

Model LL100XL Suitable for water heaters with up to

2

1

2

" (63.5mm) of insulation

Model LLL100XL Suitable for water heaters with up to

3" (76mm) of insulation

ModeL

Size

WidTh

WeighT

C.S.A TeMP

STeAM RATing

A

B

C

D

E

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

Kgs

SL100XL

3

4

20

1

7

8

48

3

15

16

100

2

1

2

63

1

7

8

47

1

1

4

31

3

5

16

84

.58

.26

105,000 BTU/hr

L100XL

3

4

20

1

7

8

48

4

5

16

109

2

13

16

71

2

3

16

56

1

9

16

40

2

15

16

75

.61

.28

105,000 BTU/hr

LL100XL

3

4

20

1

7

8

48

4

13

16

122

3

5

16

84

2

11

16

68

2

1

16

53

2

7

16

62

.65

.29

105,000 BTU/hr

LLL100XL

3

4

20

1

7

8

48

5

3

16

132

3

3

4

94

3

1

8

79

2

1

2

63

2

1

16

52

.68

.31

105,000 BTU/hr

For Heaters with Direct Top Tapping

Use standard or extra length extension thermostat.

A

B

C

d

e

1"

(25mm)

Dimensions — Weights

ES-SL-100XL/L100XL/LL100XL/LLL100XL 1205

© 2012 Watts

USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com

Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

A Watts Water Technologies Company

REINSPECTION OF T&P RELIEF VALVE: Temperature and

Pressure Relief Valves should be reinspected AT LEAST

ONCE EVERY THREE YEARS by a licensed plumbing contrac-

tor or authorized inspection agency, to insure that the product

has not been affected by corrosive water conditions and to

insure that the valve and discharge line have not been altered

or tampered with illegally. Certain naturally occurring conditions

may corrode the valve or its components over time, rendering

the valve inoperative. Such conditions are not detectable unless

the valve and its components are physically removed and in-

spected. Do not attempt to conduct this inspection on your own.

Contact your plumbing contractor for a reinspection to assure

continuing safety.

FAILURE TO REINSPECT THIS VALVE AS

DIRECTED COULD RESULT IN UNSAFE TEMPERATURE

OR PRESSURE BUILD-UP WHICH CAN RESULT IN SERI-

OUS INJURY OR DEATH AND/OR SEVERE PROPERTY

DAMAGE.

IMPORTANT: A relief valve functions in an emergency by

discharging water. Therefore, it is essential that a discharge line

be piped from the valve in order to carry the overflow to a safe

place of disposal. The discharge line must be the same size as

the valve outlet and must pitch downward from the valve and

terminate at least 6"(152mm) above the floor drain where any

discharge will be clearly visible. For 100DT discharge line consult

your Watts agent.