Month system maintenance annual maintenance – Watts PWDWUFKC3 User Manual

Page 7

background image

7

Order filter by calling Watts at 1-800-224-1299
Item Needed: EDP# 7100116

Includes:

• (1) Sediment Filter

• (1) Carbon Block Filter

Note: Your UF Drinking Water Module is equipped with valved

heads which will automatically turn off the water supply to each

filter when the filter is released, thus you do not need to turn off

the incoming water supply at the Adapt-A-Valve™. The faucet

must be off when filters are replaced.

Step A – Place the towel under the UF Drinking Water Module to

catch any excess water that drips out from the filters during

the changeover .

Step B – To make the removal of the

filter housings easier, the heads

& housings may be lifted up

to 90 degrees as shown in the

pictures to the right . Starting

with the sediment filter, lift the

cartridge up to 90 degrees .

Rotate the cartridge a

1

4

turn

counterclockwise, remove and

dispose of used cartridge .

Step C – Make sure to remove the

cap off of the new replace-

ment filter . Insert the new filter

cartridge into the head and

rotate it clockwise

1

4

turn until

it stops . Return cartridge to the

vertical position .

Step D – Repeat this procedure for the

2nd filter cartridges . When

finished, flush your tank com-

pletely once to remove any nat-

ural carbon fines from the UF

Drinking system . Check over

the next 24 hours to ensure no

leaks are present .

Photographs for reference purposes

only for Kwik-Change™ drinking water

systems . Your system may contain 2, 3,

or 4 filter cartridges .

6-Month System Maintenance

Annual Maintenance

Order filter by calling Watts at 1-800-224-1299
Item Needed: EDP# 7100118

Includes:

• (1) Sediment Filter

• (1) UF Membrane

• (1) Carbon Block Filter

Note: Your UF Drinking Water module is equipped with valved

heads which will automatically turn off the water supply to each

filter when the filter is released, thus you do not need to turn off

the incoming water supply at the Adapt-A-Valve™. The faucet

must be off when filters are replaced.
Step A – Place the towel under the UF Drinking water module to

catch any excess water that drips out from the filters during

the changeover .

Step B – To make the removal of the

filter housings easier, the heads

& housings may be lifted up

to 90 degrees as shown in the

pictures to the right . Starting

with the sediment filter, lift the

cartridge up to 90 degrees .

Rotate the cartridge a

1

4

turn counterclockwise, remove

and dispose of used cartridge .

Step C – Make sure to remove the

cap off of the new replace-

ment filter . Insert the new filter

cartridge into the head and

rotate it clockwise

1

4

turn until

it stops . Return cartridge to the

vertical position .

Step D – Repeat this procedure for the

2nd and 3rd filter cartridges .

When finished, flush your tank

completely once to remove

any natural carbon fines from

the UF Drinking Water system .

Check over the next 24 hours

to ensure no leaks are present .

Photographs for reference purposes only for Kwik-Change™ drinking

water systems . Your system may contain 2, 3, or 4 filter cartridges .