STEP 4

System Start Up

Step A– Turn on water supply at angle stop and open the Adapt-

A-Valve™ . Turn faucet handle to the open position to start

the flow of water through the unit . Run 3 gallons of water

through the unit in order to flush out the normal black car-

bon fines (it will “sputter” until the air is purged out) from the

unit . Initially, the water may appear cloudy which is due to

tiny air bubbles and it will clear up shortly . Close the faucet

when finished .

Step B – Check for leaks . If you have any leaks, shut off the water

supply to your system, tighten any fittings / housings and

restart unit .

Check frequently over the next 24 hours to ensure no leaks are

present

Green Tube Connection

Step A – Locate green tube attached to the

Filter Module . Insert the open end

of the green

1

4

" tube into the open

1

4

" Quick-Connect fitting on the

Adapt-A-Valve™ making sure the

tube is pushed in all the way to the

tube stop .

Step B – Connect the green tube from the

Filter module to the Adapt-A-Valve™

that is connected to the angle stop

valve . Leave enough tube so it is not kinked and cut the

tube to the desired length .

STEP 5

UF Drinking System Module Mounting

Step A – Determine best location for

the UF Filter Module to be

mounted to allow for future

system maintenance . The

parts bag has 2 self-tapping

screws . Using an electric drill

with a Phillips bit, screw them

into the cabinet wall 6" apart

and 16" from the bottom of the

cabinet .

Note: Do not cut any UF system tubes at this time