12. The natural gas inlet pressure at the grill is to be set at 7.0" of

inlet pressure.

13. Ignite burner on grill and observe flame pattern. If flame is yel-

low in color or flame is lifting off burner, the air shutter on blue

flame burners only will require adjustment.

14. Beneath the control panel you can access the air shutter

which is located on the end of the burner tube.

15. Loosen phillips screw at air shutter, open air shutter for a yel-

low flame or close air shutter for a lifting flame. Tighten phillips

screw at air shutter.

16. Ignite burners on grill to verify burner flame characteristics.

17. Replace briquet rack and briquets and reinstall cooking grids.

Installation must conform to local codes or in the absence of local

codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54,

Natural Gas and Propane Installation Code, CSA B149.1, or Pro-

pane Storage and Handling Code, B149.2.

Caution: The grill and its individual shutoff valve must be dis-

connected from the gas supply piping system during any sys-

tem pressure testing at test pressures in excess of 1/2 PSIG.

Caution: The grill must be isolated from the gas supply piping

system by closing its individual manual shutoff valve during

any pressure testing of the gas supply piping system at test

pressures equal to or less than 1/2 PSIG.