Natural gas grills, Connection requirements, Hazardous locations and conditions – Broilmaster P4XF-1 User Manual
Page 21: Grill location
B101623-2-0112
Page 21
Connection Requirements
Broilmaster grills are not equipped with pressure regulators. Your
gas grill operates at a manifold pressure of seven (7") inches water
column.
Connect cart mounted Natural gas grills to a pre-installed gas sup-
ply line using the twelve (12’) foot flexible hose and quick disconnect
kit which can be purchased from your local dealer.
Hazardous Locations and Conditions
•
The LP gas cylinder must be arranged upright for vapor with-
drawal.
•
Do not obstruct the flow of combustion and ventilation air.
•
This grill should only be used outdoors in a well-ventilated space
must not be used in a building, garage, or any other enclosed
area.
•
Keep all flammable substances away from the grill. These
include most aerosols and aerosol containers, gasoline and
similar liquids, paper and paper products, containers of grease,
paint, etc.
•
Never store flammable materials or objects such as those
described above in the pedestal base.
•
Never leave grill unattended while in operation.
•
Never use any liquid in an attempt to control flare-up.
•
It may be necessary to adjust your grill away from the direction
of prevailing wind.
•
Avoid wearing flammable and/or loose clothing such as long-
sleeves, neckties, scarves, aprons, etc., while the grill is in
operation.
•
Avoid contact of hair to heat and flames.
Caution: The grill and its individual shutoff valve must be
disconnected from the gas supply piping system during any
system pressure testing at test pressures in excess of 1/2 PSIG.
Caution: The grill must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSIG.
Grill Location
When choosing the ideal location for your Broilmaster Premium
Gas Grill, remember this grill is designed for outdoor use ONLY.
You should never install or operate your grill in any building, garage,
or other enclosed area.
For your safety, this grill should not be installed or operated under
any combustible materials, such as carports, covered porches,
awnings, or overhangs.
Never install or operate your grill in or on any recreational vehicle
or boat.
CAUTION: The installation and operation of this grill at clear-
ances less than specified below may lead to the possibility of
fire, property damage, or personal injury.
A minimum clearance of sixteen (16") inches is required from the
sides of the grill to any combustible material.
A minimum clearance of eighteen (18") inches is required from the
back of the grill to any combustible material.
Some examples of combustible materials are a wall, a fence, patio
furniture, or the wall of your home.
The area surrounding the grill should be clear to ensure proper
ventilation. Do not obstruct the flow of combustion and ventilation
air in any way. The ventilation openings on the propane cylinder
enclosure must also remain free and clear of debris.
Portable grills should be level and positioned away from direct wind
prior to each use.
WARNING: Do not install or operate this grill where gaso-
line or other flammable materials are used or stored. Failure
to comply with this warning could result in explosion or fire
causing property damage or personal injury.
Gas Type
The type gas required for your grill can be determined from the
product identification label located on the grill’s control panel.
Questions regarding different types of gases should be directed to
your local gas supplier.
Caution: Never use Liquid Propane (LP) gas in a grill designed
for Natural gas, or Natural gas in a grill designed for Liquid
Propane gas. Questions regarding different types of gases
should be directed to your local gas company.
NATURAL GAS GRILLS