Connection Requirements

Broilmaster grills are not equipped with pressure regulators. Your

gas grill operates at a manifold pressure of seven (7") inches water

column.

Connect cart mounted Natural gas grills to a pre-installed gas sup-

ply line using the twelve (12’) foot flexible hose and quick disconnect

kit which can be purchased from your local dealer.

Hazardous Locations and Conditions

The LP gas cylinder must be arranged upright for vapor with-

drawal.

Do not obstruct the flow of combustion and ventilation air.

This grill should only be used outdoors in a well-ventilated space

must not be used in a building, garage, or any other enclosed

area.

Keep all flammable substances away from the grill. These

include most aerosols and aerosol containers, gasoline and

similar liquids, paper and paper products, containers of grease,

paint, etc.

Never store flammable materials or objects such as those

described above in the pedestal base.

Never leave grill unattended while in operation.

Never use any liquid in an attempt to control flare-up.

It may be necessary to adjust your grill away from the direction

of prevailing wind.

Avoid wearing flammable and/or loose clothing such as long-

sleeves, neckties, scarves, aprons, etc., while the grill is in

operation.

Avoid contact of hair to heat and flames.

Caution: The grill and its individual shutoff valve must be

disconnected from the gas supply piping system during any

system pressure testing at test pressures in excess of 1/2 PSIG.

Caution: The grill must be isolated from the gas supply piping

system by closing its individual manual shutoff valve during

any pressure testing of the gas supply piping system at test

pressures equal to or less than 1/2 PSIG.

Grill Location

When choosing the ideal location for your Broilmaster Premium

Gas Grill, remember this grill is designed for outdoor use ONLY.

You should never install or operate your grill in any building, garage,

or other enclosed area.

For your safety, this grill should not be installed or operated under

any combustible materials, such as carports, covered porches,

awnings, or overhangs.

Never install or operate your grill in or on any recreational vehicle

or boat.

CAUTION: The installation and operation of this grill at clear-

ances less than specified below may lead to the possibility of

fire, property damage, or personal injury.

A minimum clearance of sixteen (16") inches is required from the

sides of the grill to any combustible material.

A minimum clearance of eighteen (18") inches is required from the

back of the grill to any combustible material.

Some examples of combustible materials are a wall, a fence, patio

furniture, or the wall of your home.

The area surrounding the grill should be clear to ensure proper

ventilation. Do not obstruct the flow of combustion and ventilation

air in any way. The ventilation openings on the propane cylinder

enclosure must also remain free and clear of debris.

Portable grills should be level and positioned away from direct wind

prior to each use.

WARNING: Do not install or operate this grill where gaso-

line or other flammable materials are used or stored. Failure

to comply with this warning could result in explosion or fire

causing property damage or personal injury.
Gas Type

The type gas required for your grill can be determined from the

product identification label located on the grill’s control panel.

Questions regarding different types of gases should be directed to

your local gas supplier.

Caution: Never use Liquid Propane (LP) gas in a grill designed

for Natural gas, or Natural gas in a grill designed for Liquid

Propane gas. Questions regarding different types of gases

should be directed to your local gas company.