Residential Fire Sprinkler Fitting
Mounting:
Predetermine suitable mounting location per fire sprinkler installation plan.
Mounting stud or joist must be square to the future finished surface for proper
alignmentof the sprinkler head.
Position the pendent fitting to the required depth on stud or joist and screw the
mounting feet securely into place. Use the proper screw for the material. Screw
should be at least 1-
1
⁄
2
" #10 course thread. For proper depth measurements,
please refer to the dimensional diagrams in the Watts NFPA 13D-Residential
Fire RF PEX
TM
Multipurpose Piping Installation guide.
L = Hmin, Hmax should be obtained from the sprinkler manufacturer information.
T = Drywall Thickness
D = Estimated Sprinkler Fitting Hole Location
Dmin = L – T– Hmax – .375.
Dmax = L – T– Hmin – .375.
T
D
L
Hmin
Hmax
2. Pipe is cut square
and stops at fitting
shoulder
4. CrimpRing is evenly
compressed over the pipe,
and shows no evidence of
uneven distortion.
1. Fitting
shoulder
location
3. CrimpRing is positioned
1/8" - 1/4" from end of the
pipe, directly over two end
ribs of fitting.
RF PEX
TM
Connection:
Cut RF PEX
TM
tubing to desired length. Make sure that tubing is cut squarely,
and all burrs are removed. Slide correctly sized crimp ring over end of tub-
ing. Remove protective caps from barbed connections on the pendent fitting
and slide tubing over the connection until the tubing touches the shoulder of
the fitting. Slide crimp ring over the tubing fitting connection until it is
1
/
8
" to
¼" from the end of tubing. The crimp ring should be positioned directly over
the two ribs closest to the end of the fitting.
Position crimp tool at a 90° angle to the pipe so that the jaws completely
cover the crimp ring. Compress the jaws completely. Check connection with
Go/No-Go gauge. If the connection does not gauge correctly, cut out the
joint, recalibrate the tool, and start again.
BEFORE INSTALLING WATTS RESIDENTIAL RF FIRE PEX
TM
COMPONENTS, YOU MUST THOROUGHLY READ THE WATTS
NFPA 13D - RESIDENTIAL FIRE RF PEX
TM
MULTIPURPOSE PIPING
INSTALLATION GUIDE AVAILABLE AT WWW.WATTS.COM FOR
FURTHER INFORMATION INCLUDING ADDITIONAL PRODUCT-
SAFETY INFORMATION AND THE PRODUCT WARRANTY.
This information is not intended to provide full installation guidelines
or the experience of a trained product installer. To the extent the Guide
is not consistent with local building or plumbing codes, the local codes
should be followed.
FAILURE TO COMPLY WITH PROPER INSTALLATION
INSTRUCTIONS COULD RESULT IN DAMAGE TO THE
MULTIPUPOSE PIPING SYSTEM, INCLUDING, THE FIRE
SUPPRESSION SYSTEM WHICH CAN RESULT IN PROPERTY
DAMAGE, PERSONAL INJURY AND/OR DEATH.
The Guide and these instructions do not address design and installa-
tion requirements for any system, nor do they address hydraulic calcu-
lations, sprinkler selection, installation and/or performance. YOU ARE
REQUIRED TO CONSULT WITH A CERTIFIED FIRE PROTECTION
DESIGN PROFESSIONAL, LICENSED RESIDENTIAL FIRE
SUPPRESSION SYSTEM INSTALLER AND THE AUTHORITY HAVING
JURISDICTION WHEN INSTALLING A MULTIPURPOSE SYSTEM.
• Watts does not provide design or installation services or instructions
and shall not be held responsible for system design or installation
errors.
• This product is intended to work with residential multipurpose fire
suppression sprinklers with NFPA 13D systems rating at a maximum
of 130psi (896 kPa) at 120°F (48.9°C) when used in a multipurpose
system. The type of sprinkler for any system shall be limited to that
specified and approved by the authority having jurisdiction for the
given installation. DO NOT use this product for systems required
to meet NFPA 13, 13R or 13D stand-alone systems.
• WATTS IS NOT RESPONSIBLE FOR INADEQUATE WATER
PRESSURE OR WATER SUPPLY. Refer to a certified fire protection
design professional to ensure the proper water pressure and supply
is available for the application.
WARNING
!
• In a multipurpose system, where the residential fire PEX tubing (RF PEX
TM
tubing) serves both fire sprinklers and domestic use, devices that restrict the
water flow or decrease the pressure or automatically shut off the water to the
fire suppression system, such as water softeners, filtration systems, and auto-
matic shutoff valves, shall not be added without a review of the fire suppres-
sion system by a fire protection specialist. Additionally, appropriate signage
is required for the end user. Refer to NFPA 13D for further information.
• DO NOT use any damaged products. Before assembling any components,
inspect all products for manufacturing defects, cuts, scrapes, gauges, splits
or any other irregularities that occur during shipping and handling.
• In order to ensure proper operation of the multipurpose system, the product
must be used with Watts UL 1821 listed RF PEX
TM
tubing, residential fire PEX
fittings (RF fittings), residential fire PEX sprinkler fittings (RF PEX
TM
Series FPSF
sprinkler fittings) and CrimpRing™ connections and require protection by any
of the following: 1) 3/8" thick or thicker gypsum wallboard 2) A suspended
membrane ceiling with lay-in panels or tiles having a weight of not less than
0.35 lb/ft2 when installed with metallic support grids 3) ½" plywood
or plywood soffits.
• DO NOT use air or compressed gas for pressure testing. The use of air or
compressed gas can cause system failure and/or product damage, property
damage, personal injury and/or death.
• These products are designed for use in environments with ambient tempera-
ture ranges between 40°F and 120°F. DO NOT allow the multipurpose system
to freeze. Freezing temperatures can damage component parts causing water
damage and/or damage to the fire suppression system which can result in
property damage, personal injury and/or death.
• In order to prevent damage to the Watts components, avoid over torqueing
when installing the sprinkler into the multipurpose system. Refer to the
sprinkler manufacturer’s instructions for proper installation requirements.
• Periodic Maintenance is required pursuant to the Guide, NFPA 13D and local
and national codes.
IS-FPSF
1116
EDP# 2915858
© Watts,
2011
US
A:
815
C
hes
tnu
t S
t.,
No.
A
ndo
ver
, M
A 0
184
5-6
098
; w
ww
.w
att
s.c
om
Can
ad
a:
543
5 N
ort
h S
erv
ice
R
d.,
Bur
lin
gto
n,
ON
. L
7L
5H
7;
ww
w.w
att
sca
nad
a.c
a
IS-FPSF
1116
EDP# 2915858
© Watts,
2011
US
A:
815
C
hes
tnu
t S
t.,
No.
A
ndo
ver
, M
A 0
184
5-6
098
; w
ww
.w
att
s.c
om
Can
ad
a:
543
5 N
ort
h S
erv
ice
R
d.,
Bur
lin
gto
n,
ON
. L
7L
5H
7;
ww
w.w
att
sca
nad
a.c
a
IS-FPSF
Serie FPSF
Empalme de
aspersor para
incendios residenciales
Tam
año
s: 2
0 –
25
m
m (¾
p
ulg
. –
1
pul
g.)
Autorizado por
UL 1821
Série FPSF
Raccord de
gicleur résidentiel
Tai
lle
s :
20
mm
et
25
m
m (0
,75
p
o e
t 1
p
o)
Homologué UL
1821
Series FPSF
RF
PEX
TM
R
esi
den
tia
l
Fire
S
prin
kle
r F
itti
ng
Siz
es:
3
⁄
4
" –
1"
(2
0 –
25
mm
)
UL
182
1 li
ste
d
FPSF-2 Tee
Fitting
FPSF-2 Empalme
en T
Raccord en
T FPSF-2
FPSF-1S
Straight Fitting
FPSF-1S
Empalme recto
Raccord droit
FPSF-IS
FPSF-1L Left
Fitting
FPSF-1L
Empalme a
la izquierda
Raccord côté
gauche FPSF-1
L
FPSF-1R Right
Fitting
FPSF-1R Empalme
a la
derecha
Raccord côté
droit FPSF-1R
3
⁄
4
" -
1
" (2
0-2
5m
m)
Ins
tal
lat
ion
In
str
uct
ion
s
Ins
tru
cci
one
s d
e in
sta
lac
ión
Ins
tru
ctio
ns
d’in
sta
lla
tio
n