beautypg.com

X100 p h, Controller features – Watts ProSense User Manual

Page 4

background image

4

CONTROLLER FEATURES

Display Icons & Cursors

Time/Day

Regeneration Time

Salt Amount

Capacity

SU MO TU WE TH FR SA DAYS

Hardness

g/L

PM

MIN

KG

x2

x100

P

H

C

Lbs/ft

3

2

1

3

4
5

6

17

18

19

20

21

22

23

24

25

26

11

12

15

13

14

16

9

10

8

7

NOTE: In normal operation and during programming, only

a few of the icons are actually displayed.

1. This cursor is displayed when the days between

regeneration are being programmed (used with .5 to 30 day

regeneration programming).

2. One of these cursors is displayed to indicate which day will

be programmed into the controller.

3. "PM" indicates that the time displayed is between 12:00

noon and 12:00 midnight (there is no AM indicator). PM

indicator is not used if clock mode is set to 24-hour.

4. When "MIN" is displayed, the value entered is in minute

increments.

5. When g/L is displayed, the value for regenerant amount

entered is in grams/Liter of resin.

6. When "Kg" is displayed, the value entered is in kilograms or

kilograins.

7. Four digits used to display the time or program value. Also

used for error codes.

8. Colon used as part of the time display.
9. Locked/unlocked indicator. In Level I Programming this

is displayed when the current parameter is locked-out.

It is also used in Level II Programming to indicate if

the displayed parameter is locked (icon flashes) when

controller is in Level I.

10. When "x2" is displayed, a second regeneration has been

called for.

11. The recycle sign is displayed (flashing) when a

regeneration at the next time of regeneration has

been called for. Also displayed (continuous) when in

regeneration.

12. The display cursor is next to "SALT AMOUNT" when

programming the amount of regenerant.

13. The display cursor is next to "REGENERATION TIME"

when programming the time of regeneration and the days

of regeneration.

14. The display cursor is next to "TIME/DAY" when

programming the current time and day.

15. The hourglass is displayed when the motor is running. The

camshaft should be turning.

16. These cursors appear next to the item that is currently

displayed.

17. X100 multiplier for large values.
18. When Lbs/ft3 is displayed the value for regenerant amount

entered is in pounds/cubic foot of resin.

19. Faucet is displayed when the current flow rate is displayed.

Control may show the faucet and "0", indicating no flow.

20. Maintenance interval display turns on if the months in

service exceed the value programmed in P11.

21. Displays the tank in service durning normal operating

mode. Used with #22, #23 and #24 in programming mode

or regeneration.

22. History Values (H). The number displayed by #23 identifies

which history value is currently displayed.

23. Parameter (P). Displayed only in Level II Programming.

The number displayed by #21 identifies which parameter is

currently displayed.

24. Cycle (C). The number displayed by #21 is the current

cycle in the regeneration sequence.

25. Hardness setting.
26. Capacity display—shows estimated system capacity

Check Salt Light
A check salt LED light indicator is located at the bottom

left of the controller keypad buttons. This light indicates, by

illuminating, that the conductivity probes did not see a shift in

conductivity during the last service cycle before regeneration

was called for by the meter. This could be an indicator that the

brine tank is out of salt. It could also indicate that the hardness

of the feed water has come down and the hardness value

programmed in Level 1 Programming needs to be adjusted to

a more accurate value. Upon start up of a new system this light

will stay illuminated until the resin has exhausted a few times.

Then it will turn off and function normally.