Performance, Ordering information – Watts PWR4021 User Manual
Page 3
![background image](/manuals/589395/3/background.png)
Performance
Maximum Productivity (gallons per day)
3600
5400
7200
9000
10,800
Quality (typical membrane percent rejection)
98 %
% Recovery (adjustable)
25 - 75
36 - 75
42 - 75
46 - 75
50 – 75
Membrane Size
4” x 40”
Number Of Membranes
2
3
4
5
6
Prefilter
(systems ship with one 5 micron cartridge)
20" BB
Feed Water Connection
1" FNPT
Product Water Connection
3
⁄
4
" FNPT
Reject Water Connection
3
⁄
4
" FNPT
Feed Water Required (GPM at 50% recovery)
5
7.5
10
12.5
15
Feed Water Pressure (minimum)
20 psi
Drain Required (maximum)
15 gpm
Electrical Requirement
(other voltages available)
230 VAC, 3-phase, 60 Hz, 15 amps
Motor Horse Power
5
Dimensions L x W x H (approximate)
60” x 18” x 56”
Shipping Weight (estimated pounds)
400
500
600
700
800
MODEl NO.
DESCRIpTION
PWR40213023
3600 GPD Reverse Osmosis System with Micro Processor Control and Auto Flush
PWR40213033
5400 GPD Reverse Osmosis System with Micro Processor Control and Auto Flush
PWR40213043
7200 GPD Reverse Osmosis System with Micro Processor Control and Auto Flush
PWR40213053
9000 GPD Reverse Osmosis System with Micro Processor Control and Auto Flush
PWR40213063
10,800 GPD Reverse Osmosis System with Micro Processor Control and Auto Flush
Ordering Information
Notes:
For all other guideline information please contact your Watts representative.
Published maximum production rates are based on a feed water of 77°F, SDI of less
than 3, 1000 ppm TDS, and pH 8.
Individual membrane productivity may vary (± 15%). May be operated on other feed
waters with reduced capacity.
Percent rejection is based on membrane manufacturer’s specifications; overall system
percent rejection may be less.