beautypg.com

Specifications, Feed water guidelines, Dimensions - weights – Watts PWR4021 User Manual

Page 2

background image

Specifications

Watts Pure Water Series PWR4021 reverse osmosis system

shall be installed to provide reverse osmosis quality water. The

RO system shall be installed after a Series PWS water softener

so that scale forming calcium and magnesium hardness cannot

scale the RO membranes. Series PWC backwashing carbon fil-

ter shall be installed on the RO feed water line to remove chlo-

rine and prevent membrane degradation due to chlorine attack.

Series PWM backwashing sediment filter shall also be installed

on the RO feed water line to reduce the silt density index of the

water to prevent particulate fouling of the RO membranes.
The RO system shall be a high-pressure/high-rejection type

unit complete with permeate and reject water flow meters,

reject recycle water flow meter, 316L stainless steel membrane

housings, pre-filter inlet and outlet pressure gauges, membrane

feed and reject water pressure gauges, automatic inlet sole-

noid valve, low feed water pressure switch, reject and recycle

valves, digital controller with conductivity meter and high-

conductivity alarm output, storage tank level and pretreatment

interlock inputs, 5 horse power multistage centrifugal high-

pressure pump, and all other components necessary for proper

operation. The system shall be a floor mount design. The RO

permeate water shall be collected in an atmospheric storage

tank with the tank level controlled by an electronic level float.

The RO shall be equipped with inputs for the tank level float as

well as pretreatment interlock to shut the RO system down in

the event the pretreatment begins a backwash cycle. Electrical

requirements are 230 volt 60 hertz three phase. A local drain is

required to accept drain water from the system. The feed water

pressure must not fall below 20psi. The feed water temperature

must not fall below 35°F or exceed 100°F (2° - 38°C).
The system shall produce reverse osmosis quality water with

95 percent minimum average ionic rejection of total dissolved

solids when operated within the manufacturer’s operational

specifications.

Feed Water Guidelines

pH . . . . . . . . . . . . . . . . . . . . . . . . . 6 to 9
Hardness (maximum) . . . . . . . . . . . Less than 1 grain per gallon as

CaCO3 (Softened) or anti scale

chemical injection if not softened

(contact your Watts representative)

Feed Water Pressure (minimum) . . . 20psi
Temperature . . . . . . . . . . . . . . . . . . 35 - 100°F (2 - 38°C)
Free Chlorine (maximum) . . . . . . . . None Allowed
Iron (maximum) . . . . . . . . . . . . . . . Less than .1mg/L
Oil and H2S . . . . . . . . . . . . . . . . . . None Allowed
Turbidity . . . . . . . . . . . . . . . . . . . . . Less than 1.0 NTU
Silt Density Index . . . . . . . . . . . . . . Less than 5.0 SDI

Dimensions - Weights

A

C

B

FRONT

SIDE

MODEl NO.

DIMENSIONS

WEIghTS

A B C

in. mm

in.

mm

in.

mm

lbs.

kg

PWR40213023 18 457 56

5

16

1430 50 1270 400 182

PWR40213033 18 457 56

5

16

1430 50 1270 500 227

PWR40213043 18 457 56

5

16

1430 50 1270 600 273

PWR40213053 18 457 56

5

16

1430 50 1270 700 318

PWR40213063 18 457 56

5

16

1430 50 1270 800 364