Specifications

Feed water

! Do not use this system on water that is microbiologically unsafe or

of unknown quality without adequate disinfection before or after the

system !
Minimum inlet pressure: 20 psig
Maximum operating pressure: 125 psig
Minimum water temperature: 34°F (1°C)
Maximum water temperature: 110°F (43°C)
Power
Voltage: 120VAC
Frequency: 60Hz
Power consumption: 7 Watts Maximum
Installation
Location: Indoors (Protect from direct sunlight)
Minimum ambient temperature: 34°F
Maximum ambient temperature: 122°F
Brine Tank Salt Capacity
32K, 45K & 60K = 300 lbs.
90K & 120K = 400 lbs.
Drain Flow Rates
32K - (1.0 ft

3

resin) – rated drain flow during regeneration – 2.0 gpm

45K - (1.5 ft

3

resin) – rated drain flow during regeneration – 2.4 gpm

60K - (2.0 ft

3

resin) – rated drain flow during regeneration – 3.5 gpm

90K - (3.0 ft

3

resin) – rated drain flow during regeneration – 4.0 gpm

120K - (4.0 ft

3

resin) – rated drain flow during regeneration – 7.0 gpm

Shipping Weights - approximate
30K – 112 lbs
45K – 130 lbs
60K – 190 lbs
90K – 265 lbs

Setup

Unpack and check the system components for damage or missing

parts.

Where to Install the Softener

Consider the following points when determining where to install the

water softener:
• Place the system as close as possible to a sewer drain.
• Do not install the softener where it would block access to the water

heater, or access to the main water shutoff, water meter, or electri-

cal panels.

• Keep outside faucets on hard water to save soft water and salt.
• Install the softener in a place where water damage is least likely to

occur if a leak develops.

• A 120VAC electrical outlet is needed to plug in the transformer. If

the outlet is remote (up to 100 feet), use 18 gauge wire to connect.

• Always connect the system to the main water supply pipe before

the water heater.

• Install the system where it will not be subject to temperatures

outside of the limits stated in the Specification section or to direct

sunlight.

Determine Hardness Setting

Municipal Water
It is recommended that you call your local water company to deter-

mine your water hardness in grains per gallon and iron in mg/l (or

ppm).
Well Water
It is recommended that you have your water tested professionally for

accurate hardness and iron content.