Specifications, Battery replacement warnings – Banner SureCross DX81H Battery Supply Module User Manual
Page 2

6. After replacing the battery, allow up to 60 seconds for the device to power up.
7. Properly dispose of your used battery according to local regulations by taking it to a hazardous waste collection site, an
e-waste disposal center, or any other facility qualified to accept lithium batteries.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn
or expose them to high temperatures. Do not recharge, crush, disassemble, or expose
the contents to water.
The battery may be replaced in explosive gas atmospheres.
Replacement battery model number: BWA-BATT-001. For pricing and availability,
contact Banner Engineering.
Battery Replacement Warnings
WARNING:
•
Do not replace battery when an explosive dust atmosphere may be present.
•
The replacement battery MUST be a Banner approved battery, model number BWA-BATT-001.
Use of a different battery will VOID the intrinsic safety rating of this device and may result in an
explosion!
•
When replacing the battery, the negative end of the battery holder is the side with the spring
terminal. This side is marked with a minus (−) sign.
•
Do not attempt to recharge the battery. These batteries are not rechargeable. Recharging may
cause serious injury to personnel or damage the equipment. Replace only with factory
recommended batteries.
Specifications
General
Environmental
Estimated Battery Life
19,000 mA·hours
Housing
Polycarbonate housing and rotary dial cover; polyester
labels; EDPM rubber cover gasket; nitrile rubber, non-
sulphur cured button covers
Weight: 0.26 kg (0.57 lbs)
Mounting: #10 or M5 (SS M5 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)
Wiring Access
One 1/2-inch NPT with 5-pin Euro-style 150 mm
pigtail QD
Environmental
Rating: IEC IP67; NEMA 6; (See UL section below for
any applicable UL specifications)
Operating Temperature: −40 to 70 °C
Operating Humidity: 95% max. relative (non-
condensing)
Radiated Immunity: 10 V/m, 80-2700 MHz
(EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Certification
DX99 Polycarbonate Housings
CSA: Class I, Division 1, Groups A, B, C, D (Ex ia IIC / AEx ia IIC T4 ) Certificate: CSA 2008243
LCIE/ATEX: Zone 0 (Category 1G), Temperature Class T4 (II 1 G / Ex ia IIC T4) Certificate: LCIE 08 ATEX
6098 X
Notes: Special Conditions for Safe Use imposed by Intrinsic Safety Certificate LCIE 08 ATEX 6098 X: Ambient
temperature range is –40 to 70 °C. SureCross
®
DX99 FlexPower devices can only be connected to Intrinsically Safe
certified equipment or simple apparatus as defined by EN 60079-11. All connected equipment must comply with the
Entity Parameters (Safety Parameters) listed in the
lithium battery manufactured by XENO, type XL-205F.
SureCross DX81H Battery Supply Module for the DX99
2
www.bannerengineering.com - tel: 763-544-3164
P/N 141517 Rev. B