Push Button

0.04 seconds < "Click" < 0.8

seconds

Remote Line

0.04 seconds < T < 0.8 seconds

Result

TEACH Unacceptable

Power LED: OFF
Bar graph: #1, 3, 5, 7 alternately flash
to show failure
Sensor returns to Run mode without changing settings

Single-Point Window Set

• Sets a single ON condition that extends 12.5% above and below the taught condition
• All other conditions (lighter or darker) result in OFF output
Sensing window size (sensitivity) is adjustable using “+” and “-” buttons (see

Manual Adjust

on page 9)

Window Set is most useful when a product may not always appear in the
same place, or when other signals may appear. Window Set designates a
sensing window, with the Output ON condition inside the window, and the
Output OFF conditions outside the window. The sensor accepts a single
sensing condition, and adds switching thresholds above and below that con-
dition to create a sensing window. Output ON and OFF conditions can be re-
versed by changing Light/Dark Operate status in Setup mode.
Window Set and Manual Adjust
Using Manual Adjust with Window Set expands or contracts the size of the
window. The lighted LEDs on the light bar separate to a greater or lesser ex-
tent to exhibit the relative sensing window size.

Sensor positions

window thresholds

± 100 counts from the

presented condition

Darkest

(no signal)

Most Light
(saturated

signal)

Taught

Condition

200 counts

Hysteresis

100 counts

Hysteresis

100 counts

Output OFF

Output OFF

Output ON

Sensing window size adjusted by

Manual Adjust

Figure 3. Single-Point Window SET and Hysteresis

(Light Operate shown)

Push Button

0.04 seconds < "Click" < 0.8 sec-

onds

Remote Line

0.04 seconds < T < 0.8 seconds

Result

Access SET Mode

• Press and hold Static button > 2

seconds

• Single-pulse remote line

T

Power LED: OFF
Output LED: ON (Push Button)
Output LED: OFF (Remote)
Status LEDs: LO & DO alternately flashing

SET Sensing Condi-

tion

• Present sensing condition
• Double-click Static button.

• Present sensing condition.
• Double-pulse remote line

T

T

T

Window Accepted

Power LED: ON
Bar graph: 2 indicators flash together
to show Window accepted
Sensor returns to Run mode with new settings

Window Unacceptable

Power LED: OFF
Bar graph: #1, 3, 5, 7 flash
to show failure
Sensor returns to "SET Sensing condition"