3) Power for External Devices (all models)
External 10 to 30V dc devices such as
self-contained sensors may be connected
between terminals #3 (+) and #1 (-) of
any CD series MAXI-AMP module.
Terminal #3 offers 40mA maximum.
This is sufficient to power most Banner
self-contained dc sensors.
As the example at the right illustrates, the
current sinking output of a self-contained
sensor powered by the MAXI-AMP may
be used as the input to the AUXILIARY
terminal of a CD5 module.
See Hookup Diagram #1 (above) for load and power connection information.
2) Logic Level NPN Output (CD3 models)
Typically, the CM5 module would be
programmed for the ONE-SHOT or
DELAYED ONE-SHOT logic func-
tion. If the SP12 pair "sees" an ac-
ceptable condition when the SP300D
senses the leading (or trailing) edge
of a product, the CD3 will inhibit a
reject pulse from occuring.
The AUXILIARY terminal (#9) of models CD3A, CD3B, CD3RA and
CD3RB modules offers a logic-level NPN (current sinking) output which
may be used as a fast-response solid-state inhibit signal to the AUXILIARY
input of MAXI-AMP CD5, CL5, CM5, or CR5 Series modules. This output
may also serve as an input to any
MICRO-AMP™, Plug Logic, or CL
Series logic module. In addition,
this output may interface to other
dc devices or circuits like counters,
rate meters, or programmable logic
controllers. Switching capacity is
20mA at 12V dc.
The example here shows the use of
SP12 Series sensors and a CD3 mod-
ule to provide inspection informa-
tion, with the SP300D functioning
as a product (GATE) sensor.
green
black
white
green
red
black
white
Gate
(Interrogate)
Data
(Inspection)
Inhibit
AC
Supply
CD3
models
8
7
6
5
4
9
10
11
1
2
3
AC
Supply
CM5
models
8
7
6
5
4
9
10
11
1
2
3
SP300D
SP12 Series Emitter
SP12 Series Receiver
blue
brown
NOTE: Black wire from
SE612
is not used
+15V dc
(#3)
GATE
(Interrogate)
CD5
models
Inhibit
White
green
blue
black
white
AC
Supply
Blue
(#1)
Brown
+15V dc @40mA
DATA
(Inspection)
SE612
8
7
6
5
4
9
10
11
1
2
3
brown
SP12 Series Emitter
SP12 Series Receiver
SP12 Series sensors are especially designed for use with CD Series modules. The basic hookup is given here. Each MAXI-AMP™ CD Series module supports
use of one pair of SP12 Series sensors. CD5 Series module models also support use of a GATE or INHIBIT sensor at pin #9 (below, this page).
1) Hookup of SP12 Series Sensors (all models)
MAXI-AMP CD Series
SP12 Sensor Hookup to CD Series MAXI-AMP™ Modules
3
SPDT
5A
Relay
Output
AC
SUPPLY
*
LED + (white)
LED - (blue)
COMMON (black)
PT - (blue)
AUX
AC
SUPPLY
*
PT + (brown)
AC Load
DC Load
Load
Common
Models with isolated solid-state contacts
LED + (white)
LED - (blue)
COMMON (black)
PT - (blue)
AUX
CD3RA
CD3RB
CD5RA
CD5RB
8
7
6
5
4
9
10
11
1
2
3
PT + (brown)
SP12SELQD
Models with electromechanical relay contacts
*105 to 130V ac or 210 to 250V ac, 50/60Hz, depending on model. To power the MAXI-AMP™ module from a dc supply,
connect +12 to 28V dc at 70mA to terminal #3 and dc common to terminal #1. Make no connection to terminal #7 or #8.
SP12SRLQD
CD3A
CD3B
CD5A
CD5B
8
7
6
5
4
9
10
11
1
2
3
SP12SELQD
SP12SRLQD