Installation
Consider ergonomic principles to avoid unnecessary fatigue in the installation of the hand controls. Install the touch buttons at a height
and in a location that will be comfortable for the user.
The following figure shows two methods for mounting the touch buttons, to prevent accidental switch actuation. When mounting them on
top of the control bar, the protective field covers should be in place, as shown; or for added protection, mount the touch buttons sideways
under and/or behind a protective hood, rather than on top of the bar, without using the field covers. This side mount prevents an object
from being left in the path of the beam. In addition, shields, covers, rings, collars, dividers, or similar protection may be used to prevent
accidental switch actuation.
Figure 1. Protect VTB touch buttons to prevent defeat or inadvertent actuation
Wiring
Single-color models may be wired for either a solid or flashing job light. The wiring of two-color models determines the job light. Color
flashing job light is not available. Cabled model wiring shown. Cabled and QD model wiring is functionally identical.
• For solid color, use the standard wiring diagram.
• For flashing (2 Hz), use the alternate wiring diagrams.
One-Color Job Light, NPN
(Sinking) Output Models
One-Color Job Light, PNP
(Sourcing) Output Models
Two-Color Job Light Models
Wiring Key
Solid Job Light
Solid Job Light
NPN (Sinking) Output Models
1 = Brown
2 = Blue
3 = Black
4 = White
5 = Gray
6 = Load
7 = Job light enable
8 = Green job light
9 = Red job light
bn
bu
-
+
bk
wh
12-30V dc
Job Light Enable
0V dc
Load
bn
bu
-
+
bk
wh
12-30V dc
Job Light Enable
+10-30V dc
Load
bn
bu
-
+
bk
wh
gy
12-30V dc
Green Job Light Enable — 0V dc
Red Job Light Enable — 0V dc
Load
Flashing Job Light
Flashing Job Light
PNP (Sourcing) Output Models
Pinouts
bn
bu
-
+
bk
wh
12-30V dc
Job Light Enable
+10-30V dc
Load
bn
bu
-
+
bk
wh
12-30V dc
Job Light Enable
0V dc
Load
bn
bu
-
+
bk
wh
gy
12-30V dc
Green Job Light Enable — +10-30V dc
Red Job Light Enable — +10-30V dc
Load
2
3
4
1
2
3
4
1
5
VTB Pick-to-Light Optical Touch Button
P/N 067570 Rev. C
www.bannerengineering.com - tel: 763-544-3164
3