Ql50 luminescence sensor, Specifications – Banner QL50 Series User Manual
Page 7

P/N 112151 rev. C
7
QL50 Luminescence Sensor
Banner Engineering Corp.
•
Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Sensing Beam
Ultraviolet LED (370 nm)
Supply Voltage
10 to 30V dc, 2Vpp max ripple
30 mA max exclusive of load
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
PNP or NPN discrete output, depending on model
30V dc max
Leakage Current: <1 µA
Output Rating
100 mA maximum load
Output Protection
Protected against output overload and short circuit
Output Response Time
250 microseconds
Adjustments
1 push button (set), and remote program wire:
• Fine-detect autoset for Light Operate or Dark Operate
• 20 ms output OFF-delay
• Remote wire to +V dc for remote programming and/or push-button lockout
Indicators
Yellow Output LED: ON when output is conducting
Bicolor Ready/Error LED: Green ON = Default and Quick-Set programming RUN mode
Green OFF = Threshold
Green Flashing = Fine-Detection Program mode/Delay status
Green/Red bicolor flashing = programming error
Construction
ABS shock-resistant housing; glass lens and window (tilted, antireflective)
Environmental Rating
IEC IP62
Connections
4-pin Euro-style (M12) swivel QD connector. Cable required; see page 8 for available cable options.
Operating Conditions
Temperature: -25° to +55°C (-13° to +131°F)
Max. Relative Humidity: 90% at 50°C non-condensing
Data Retention
EEPROM nonvolatile memory
Sensing Range
0 to 40 mm (0 to 1.57")
Maximum signal at 10 mm (0.39")
Spot Diameter
1.5 mm @ 10 mm (0.059" @ 0.39")
Ambient Light Rejection
According to EN 60947-5-2
Shock Resistance
30 G; 3 shocks per axis; 11 ms duration
Vibration
0.5 mm (0.02") amplitude; 10 to 60 Hz frequency; 30 minutes for each X, Y, Z axis
Certifications
Specifications
LISTED
US