5

S30 Sensors – dc-Voltage Series

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Excess Gain

Performance based on use of a 90% reflectance white test card.

Fixed-Field

200

mm

Ø 16 mm spot size @ 35 mm focus

Ø 20 mm spot size @ 200 mm cutoff

Using 18% gray test card: Cutoff

distance will be 95% of value shown.

Using 6% black test card: Cutoff

distance will be 90% of value shown.

Fixed-Field

400

mm

Ø 17 mm spot size @ 35 mm focus

Ø 25 mm spot size @ 400 mm cutoff

Using 18% gray test card: Cutoff

distance will be 90% of value shown.

Using 6% black test card: Cutoff

distance will be 85% of value shown.

Fixed-Field

600

mm

Ø 17 mm spot size @ 35 mm focus

Ø 30 mm spot size @ 600 mm cutoff

Using 18% gray test card: Cutoff

distance will be 85% of value shown.

Using 6% black test card: Cutoff

distance will be 75% of value shown.

Performance Curves

Excess Gain

Beam Pattern

Opposed

Polarized

Retro

††

Focus and spot sizes are typical.

75 m

(250')

60 m

(200')

45 m

(150')

30 m

(100')

15 m

(50')

0

0

250 mm

500 mm

750 mm

250 mm

500 mm

750 mm

0

10"

20"

30"

10"

20"

30"

DISTANCE

S30 Series

Opposed Mode

7.5 m

(25')

6.0 m

(20')

4.5 m

(15')

3.0 m

(10')

1.5 m

(5')

0

0

50 mm

100 mm

150 mm

50 mm

100 mm

150 mm

0

2"

4"

6"

2"

4"

6"

DISTANCE

S30 Series

Polarized Retro

with BRT-3 Reflector

1

10

100

1 m

(3.3')

10 m

(33')

100 m

(330')

0.1 m

(0.33')

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

S30 Series

Opposed Mode

1

10

100

0.1 m

(0.33')

1 m

(3.3')

10 m

(33')

0.01 m

(0.033')

1000

E

X

C

E

S

S

G

A

I

N

DISTANCE

S30 Series

Polarized Retro

with BRT-3 Reflector

1

10

100

10 mm

(0.4")

100 mm

(4")

1000 mm

(40")

1 mm

(0.04")

E

X

C

E

S

S

G

A

I

N

DISTANCE

1000

S30 Series

Fixed-field mode

with 200 mm far

limit cutoff

1

10

100

10 mm

(0.4")

100 mm

4")

1000 mm

40")

1 mm

(0.04")

E

X

C

E

S

S

G

A

I

N

DISTANCE

1000

S30 Series

Fixed-field mode

with 400 mm far

limit cutoff

1

10

100

10 mm

(0.4")

100 mm

(4")

1000 mm

(40")

1 mm

(0.04")

E

X

C

E

S

S

G

A

I

N

DISTANCE

1000

S30 Series

Fixed-field mode

with 600 mm far

limit cutoff

††

Performance based on use of a model BRT-3 retroreflector (3" diameter).