CommScope PWR-COBRA-1 RET Antenna System User Manual
Page 2
Andrew,
A
CommScope
Company
3 Westbrook Corporate Center, Suite 900, Westchester, Illinois U.S.A. 60154
U.S.A.: +1 (800) 279-8185 • International: +1 (703) 726-5556
WWW.CommScope.Com
© 2008 CommScope
639568 • Revision C • November 2008
Page 2 of 6
Figure 1. RET Device Scan Results.
10. After the device scan has found all the installed antenna actuators, double click on the
serial number for the antenna actuator in the list that is to be configured.
“CONNECTED” should pop up in the Response box in the Selection area.
11. Enter the password Administrator (the password should be entered as shown with A in
upper case and the remaining letters using lower case)Click on Enable. The angle
indicator will move to the current electrical downtilt setting for the antenna.
Important Note:
Every time the Connect button is used, you must also click the Enable
button. If this is not done, errors are likely to result when reading or saving
settings in the RET.
12. Click the Settings tab (located at the top of the screen). At the bottom of the screen, click
on ALL and then click on GET. This will populate the Antenna Data section of the screen
with information that was programmed into the antenna at the factory (including model
number, serial number, frequency, gain, and the maximum and minimum tilt settings).
The Operator data section will be blank and should be filled in with the information that
was recorded on the Installation Configuration sheet in Step 1 (Figure 2).