beautypg.com

Bird Technologies 5010 Series-Manual User Manual

Page 24

background image

12

Uncertainty

b

± 8% of full-scale peak
envelope power (95%
c.l.)

Match Measurement

Match Range

Return Loss
Rho (

ρ

)

VSWR

0 to 20 dB
0.1 to 1
1.22 to 99.99

Uncertainty

Twice the Avg Power
Uncertainty
(Calculated from
forward and reflected
uncertainty)

Settling Time, Max

2.5 seconds

Impedance, Nominal

50 ohms

Insertion Loss, Max

0.05 dB up to 1 GHz

Input VSWR, Max.

1.05:1 up to 1 GHz

Directivity, Typicala

30 dB

RF Connectors

QC Type (N(F) normally
supplied)

Power Supply

From host instrument
via cable

Mechanical Shock and Vibration

In accordance with MIL-
PRF-28800F Class 3

CE

CE compliant. Refer to
DOC for specific
standards.

Recommended Calibration
Interval

1 year