Insert the forward element into the forward socket

with its arrow pointing in the direction of forward

power. Insert the reflected element into the reflected

socket with its arrow pointing in the direction of

reverse power.

Element Contact Alignment

Continuous insertion or rotation of the element might

cause a slight change in the position of the contact

spring in the element socket. If the contact spring

changes position, erratic power readings may be

experienced.
The position of the contact spring may be adjusted

with a small screwdriver to reestablish contact.

Perform the following steps to adjust the contact spring:
1. Using a small flat head screwdriver, place the flat

side of the screwdriver behind the contact bar as

indicated and bend the contact bar so that the con-

tact rests in the center of the slot adjacent to the

element socket.

CAUTION

If the element cannot be fully inserted into the

socket, do not force it. This may damage the

element.