Maintenance – Bird Technologies 8401 User Manual
Page 21
![background image](/manuals/583834/21/background.png)
Chapter 5
Maintenance
This chapter contains operator maintenance instructions,
troubleshooting, and parts information.
Troubleshooting
Cleaning
The principle maintenance required by the operator will
be the cleaning of the radiator fins. Periodically wipe
away the accumulated dust and lint. If the insulator or
metallic contact surfaces of the connector should become
dirty or grimy, wipe them off with a soft cloth and use a
contact cleaner that is self drying and leaves no residue
to clean the inaccessible internal parts.
11
Problem
Possible Cause
Remedy
Leakage of coolant oil
around band or radiator
housing.
Clamping band not
tight.
Tighten clamping band
with a screwdriver.
Faulty O-Ring (front).
Replace per the RF
Load Resistor para-
graph.
Faulty diaphragm (rear).
Replace per the Dia-
phragm and Coolant Oil
paragraph.
Overheating of the ra-
diator.
Transmitter power is
too high.
Reduce the transmitter
power.
Coolant level is too low. Add more coolant per
the Diaphragm and
Coolant Oil paragraph.
Faulty RF section.
Replace the RF section
per the RF Load As-
sembly paragraph.
High or low dc resis-
tance values.
Faulty RF input connec-
tor.
Replace per the RF
connector replacement
paragraph.
Loose RF input connec-
tor.
Tighten the connector
with a screwdriver.
Faulty RF section as-
sembly.
Replace the RF section
per the RF Load As-
sembly paragraph.