beautypg.com

Bird Technologies 8401 User Manual

Page 12

background image

service to perform their function, other than the RF input

power.

Environmental

Requirements

The load should be operated in an environment as free of

dust and vibration as possible. For proper operation the

ambient temperature should remain within the range of

-40°C to +45°C (-40°F to +113°F). Allow at least 12

inches (304.8 mm) of clear space around the load to pro-

vide an unimpeded flow of convection air currents for

adequate heat dissipation.

Items Supplied

The load is equipped with:

s

Model 8401 — Female N “QC” (quick change)

connector.

s

Model 8402 — Female C “QC” (quick change)

connector with a dust cap and secured by a

ball chain anchor.

s

Model 8404 — Female N with a Male N/Male

N adaptor, dust cap, and secured by a ball

chain anchor.

s

Instruction Manual

Item Required

Coaxial cable with the appropriate connector plug.

Tools and Test

Equipment

s

Screwdriver — for disassembly of this equip-

ment.

s

An ohmmeter with an accuracy of 1 percent or

better at 50 ohms — is recommended for

checking the resistance value of the resistor.

Bird Series 8400S Termaline Coaxial Load Resistor