4. The RF section assembly is not subject to further

disassembly in the field. A defective unit must be

returned to the factory for repair.

RF Connector

To install a new connector, reverse the procedures found in

RF Connector, Disassembly. Be sure that the projecting cen-

ter pin on the connector is carefully engaged and properly

seated in the mating socket of the load resistors and then

push it firmly home.

Coolant and

Seal

Models 8321, 8322 and 8323 - proceed as follows:

1. Inspect the output cover sealing ring (Model

8321, P/N 8321-025; Models 8322 and 8323, P/N

2430-089) on the output ring diaphragm and the

output end O-Ring (Model 8321, P/N 5-176,

Models 8322 and 8323, P/N 5-243). They should

both be soft, pliable and free of surface cracks. If

not, replace them.

2. After adding to or replacing the coolant, if re-

quired, reverse the disassembly procedure.

Model 8325

Inspect the output cover sealing ring, P/N 2430-089, on the

coolant cylinder and the output O-Ring, P/N 5-243. They

should both be soft, pliable and free of surface cracks. If not,

replace them.

Reassembly

a. If the input O-Ring is not soft, pliable and free of

surface cracks, replace it.

b. After replacing the RF load resistor assembly, if

necessary, reverse the procedure of Coolant and

Seals, Disassembly.

Repairs

Repairs, beyond what is covered in this instruction book,

will require return of the equipment to Bird Electronic Cor-

poration for service. Please consult the factory.

Shipment

Pack and brace the attenuator in a suitable shipping con-

tainer, a sturdy corrugated paper box is satisfactory. It is

not necessary to remove the dielectric coolant before ship-

ping, but do not forget to replace the vent plug with the

shipping plug on Model 8325.

Storage

No special preparations for storage are necessary other than

to cover the equipment to keep out dust and dirt. Store this

unit in a dry and dust free environment where the ambient

temperature will remain within the -40°C to +45°C (-40°F to

+113°F) working range of the equipment.