beautypg.com

Repair, Rf connector, Load resistor – Bird Technologies 8865SC13-Manual User Manual

Page 24

background image

Bird 8860 Series Semiconductor Termaline Coaxial Load Resistor

14

Repair

RF Connector

The 8865SC13 has a Bird “QC” connector which allows easy changing
of the RF connector. This does not disturb the coolant seal or affect
the electrical continuity of the load. To change the connector:

y

Remove the four screws at the corners of the RF connector.

y

Pull the connector straight out.

y

Push the new connector in. Make sure that the center pin on the
connector is properly seated in the mating socket on the load.

y

Replace the screws.

+

NOTE: If not using the LC connector normally supplied, the
frequency and power must be limited to the capabilities of the
connector.

Load Resistor

To change the load resistor assembly:

1. Remove the vent plug and install the shipping plug.

2. Supporting the unit to prevent damage to the interlock, stand it

on its back with the connector end up. In this position there is no
danger of the coolant pouring out through the resistor hole.

3. Unscrew and remove the clamping band.

4. Lift the load resistor assembly out of the tank and allow any

coolant to drip back into the tank.

5. The O-Ring should be free of twists and positioned evenly around

the flange of the resistor housing. If the O-ring shows signs of
deterioration (e.g. is no longer pliable or has surface cracks)
replace it.

6. Replace the entire load resistor assembly. It cannot be further

disassembled.

7. Put the clamping band in place and tighten it.

8. Remove the shipping plug and install the vent plug.

WARNING

Disconnect the unit from all power sources before servicing.

The unit may be energized from multiple sources.

The potential for electric shock exists.