beautypg.com

Troubleshooting – Bendix Commercial Vehicle Systems EC-14 ANTILOCK CONTROLLER 5/04 User Manual

Page 16

background image

16

Go to Section V

“Testing for Power

to the EC-14

controller”

If any other red LEDs are

illuminated, replace the EC-14

controller and repeat the “Initial

Start-up Procedure”

Is red “MOD” LED

illuminated?

Is this LED illuminated?

NO (OFF)

Is red “SENS” LED

illuminated?

YES

Note red “ECU” LED in

EC-14

controller

diagnostics window

Is the red “RIGHT” or

“LEFT” LED illuminated?

See Note 1 below

Is the red “RIGHT” or

“LEFT” LED illuminated?

SEE NOTE 1

SEE NOTE 1

TESTING

“MOD” LED

SEE NOTE 1

SEE NOTE 1

TESTING

“SENS” LED

CHECK

“ECU” LED

NO

Is the red “FRONT” or

“REAR” LED illuminated?

See Note 1 below

Is the red “FRONT” or

“REAR” LED illuminated?

See Note 1 below

NO

YES

“REAR” LED

“FRONT” LED

Go to Section VII

“Testing the Rear

Modulator”

ON?

ON?

ON?

YES

TROUBLESHOOTING

SECTION IV

INSPECTION FOR ILLUMINATED LEDs

NO

NO

YES (ON)

YES

YES

Go to Section VI

“Testing the Front

Modulator”

Replace EC-14

controller.

Repeat the “Initial

Start-up Procedure.”

Replace EC-14

controller.

Repeat the “Initial

Start-up Procedure.”

NO

Replace the EC-14

controller and repeat the

“Initial Start-up

Procedure”

NO

YES

Note the three

illuminated LEDs and

go to Section VIII

“Testing the Wheel

Speed Sensor”

1. If both of these LEDs are illuminated, replace the EC-14

controller.

NOTE

START HERE