beautypg.com

Troubleshooting – Bendix Commercial Vehicle Systems EC-14 ANTILOCK CONTROLLER 5/04 User Manual

Page 14

background image

14

Check closely: is green

LED illuminated?

Inspect EC-14

controller and record

presence of illuminated LEDs

Is green LED Flashing?

YES

YES (ON)

Are any red LED’s

illuminated?

YES

NO

NO (OFF)

Are any red LED’s

illuminated?

Go to Section IV

“Inspection for

Illuminated LEDs”

NO

Record the condition of

all red LEDs

Go to Section IX

“Testing for False Failure

Indication - Caused by Dash

Lamp Relay”

NO

Go to Section V

“Testing for Power

to the EC-14

controller”

CHECK

“VOLT” LED

YES

Go to Section V

“Testing for Power

to the EC-14

controller”

TROUBLESHOOTING

SECTION II

INSPECTION FOR ILLUMINATED LEDs

Replace EC-14

controller.

Repeat the “Initial Start-up

Procedure.”

ON?

FLASHING?

START HERE